15

1. Battery Low

7. Scan/Hold

2. Laser On/Off Indication

8. °C/ °F Indication

3. Primary Display

9. Secondary Display

4. MAX/MIN

10. Up Button

5. AVG

11. Function Key

6. Down Button

4. Operation Instructions
4-1 Quick Start 

To measure a temperature, point the unit at the target you want to measure, pull the trigger 

and hold. Be sure to consider the target area inside the angle of vision of this instrument. The 

single spot of laser is used for aiming only.

4-2 Unit diagram

A. Display Screen

B. Measuring Trigger

C. Battery Cover

•  The unit is powered by 9V battery. The User has to replace the battery when the battery  

  voltage drops below the voltage for reliable operation and at the same time the battery 

  symbol  

 will appear. 

 

D. Laser Sighting

E. Measuring Window

F. 9V Battery 

LCD & Control panel

Содержание V6299

Страница 1: ...ViGOR GmbH Am Langen Siepen 13 15 42857 Remscheid GERMANY www vigor equipment com V6299 AH I Anwendungshinweis Infrarot Thermometer V6299...

Страница 2: ...6 6 Maintenance 17 Inhaltsverzeichnis 1 Produkteinf hrung 3 1 1 Funktionsmerkmale 3 1 2 Anwendungen 3 2 Sicherheitsinformationen 3 2 1 Vorsichtsma nahmen 3 2 2 Sicherheitssymbole 4 3 Technische Daten...

Страница 3: ...aratur und Wartung von Fahrzeugen deckt die meisten industriellen und privaten Anwendungen ab Klimaanlage Forschungsexperiment Fertigungsverfahren der Halbleitertechnologie Lebensmittelsicherheit und...

Страница 4: ...edoch vorkommen dass das Ger t die angegebene Genauigkeit nicht erreicht RoHS Beschr nkung auf die Verwendung von sechs Stoffen in der elektrischen und elektronischen Ausr stung EEE um somit zum Schut...

Страница 5: ...500 ms Betriebstemperatur 0 50 C 32 122 F 10 90 RH Automatische Selbstabschaltung Automatisch nach ca 6 Sek Emissionsverm gen 0 30 0 70 0 95 10 Punkt Speicher JA C F umschaltbar JA Hintergrundbeleucht...

Страница 6: ...ckwinkel dieses Instruments befindet Der einzelne Punkt des Lasers wird nur zum Zielen verwendet 4 2 Ger teschema A Bildanzeige B Messausl ser C Deckel des Batteriefachs Das Ger t wird durch 9 V Batte...

Страница 7: ...die Daten nach dem Loslassen des Ausl sers gespeichert C F Schalter Im SCAN Modus Ausl ser loslassen und Taste dr cken Laser Schalter Im SCAN Modus Ausl ser loslassen und Taste dr cken 5 Emissionsver...

Страница 8: ...Wattest bchen abwischen Der Tupfer darf mit Wasser befeuchtet werden Hinweis KEINE L sungsmittel zur Reinigung der Linse verwenden Reinigung des Geh uses Reinigung mit Seife und Wasser auf einem feuc...

Страница 9: ...nkt hell 0 30 Eisenplatte vollst ndig 0 70 Gewalztes Stahlblech 0 70 Oxidiertes Eisen 0 70 Schmiedeeisen 0 95 Geschmolzenes Eisen 0 30 Kupfer poliert 0 30 Kupfer geschabt gl nzend nicht gespie gelt 0...

Страница 10: ...0 95 Asbestplatte 0 95 Asbestpapier 0 95 Asphalt Pflaster 0 95 Wasser 0 95 Zement 0 95 Faser 0 95 Textilien 0 95 Menschliche Haut 0 95 Papier 0 95 Holz 0 95 ViGOR GmbH Am Langen Siepen 13 15 42857 Rem...

Страница 11: ...ViGOR GmbH Am Langen Siepen 13 15 42857 Remscheid GERMANY 49 0 21 91 97 95 49 0 21 91 97 96 00 info vigor equipment com vigor equipment com 11 Application Note Infrared Thermometer V6299...

Страница 12: ...overs most industrial and residential application Air conditioner Science experiment Manufacturing processes of semiconductor technology Food safety and processing Perform HVAC energy audits 2 Safety...

Страница 13: ...x substances within electrical and electronic equipment EEE thereby contributing to the protection of human health and the environment The device may not be disposed in with the trash It promotes the...

Страница 14: ...5 C 2 7 F From 0 100 C 32 212 F 2 From 100 630 C 212 1166 F Sensor Thermopile 5 14 m Repeatability 1 C 2 F Resolution 0 1 C 0 1 F Response Time 500 ms Operation Temp 0 50 C 32 122 F 10 90 RH Auto Pow...

Страница 15: ...sure a temperature point the unit at the target you want to measure pull the trigger and hold Be sure to consider the target area inside the angle of vision of this instrument The single spot of laser...

Страница 16: ...The unit will HOLD the last reading for 6 seconds after the trigger is released When the battery is low the battery icon shows but the unit will continue to function Memory In SCAN mode the data will...

Страница 17: ...Maintenance Cleaning the lens Blow off loose particles using clean compressed air Gently brush remaining debris away with a camel s hair brush Carefully wipe the surface with a moist cotton swab The s...

Страница 18: ...ead pure 99 95 unoxidized 0 30 Copper 0 30 Steel 0 70 Zinc galvanized sheet iron bright 0 30 Brass highly polished 0 30 Brass hard rolled polished w lines 0 30 Iron galvanized bright 0 30 Iron plate c...

Страница 19: ...info vigor equipment com vigor equipment com 19 Material Emissivity Glass smooth 0 95 Granite polished 0 95 Ice 0 95 Marble light gray polished 0 95 Asbestos board 0 95 Asbestos paper 0 95 Asphalt pa...

Страница 20: ...ViGOR V6299 AH I 11 2018 Ho 114 ViGOR GmbH Am Langen Siepen 13 15 42857 Remscheid GERMANY 49 0 21 91 97 95 49 0 21 91 97 96 00 info vigor equipment com vigor equipment com 20 Notizen Notes...