Cleaning Recommendation for Vigo Products

Modern sanitary tapware, kitchen mixers and showers consist of very different materials to comply with the needs of the
market with regard to design and functionality.

To avoid damage and reclamations, it is necessary to consider certain criteria when cleaning.

Cleaning Material for Mixers and Showers

Acids are necessary ingredients of cleaning materials for removing lime, however, please pay attention to the following

points when cleaning mixers and showers:
- Only use cleaning materials which are explicitly provided for this type of application.
- Never use cleaning materials which contain hydrochloric, formic or acetic acid, as they cause considerable damage.
- Phosphoric acid is also restricted as it can cause damage to the finish.
- Never mix any cleaning material with another.
- Never use cleaning materials or appliances that have an abrasive effect, such powdered and industrial cleansers,

  scouring pads or micro fiber cloths.

Cleaning Instructions for Mixers and Showers

Please follow the instructions on your cleaning materials. In addition, pay attention to the following points:

- Clean the mixers and showers as needed and when required.
- The cleaning dosage and time the cleaner needs to take effect should be adjusted according to the product and the

  cleaner should not be left longer than necessary.

- Regular cleaning can prevent calcification.
- When using spray cleaner, spray first onto a cloth or sponge-never directly spray onto the sanitary tapware as drops could

  enter openings and gaps and cause damage.

- After cleaning, rinse thoroughly with clean water to remove any cleaner residue.

Important

Residues of liquid soaps, shampoos and shower foams can also cause damage, so rinse with clean water after using. If

the surface is already damaged, the effect of cleaning materials will cause further damage.

DAMAGE CAUSED BY IMPROPER TREATMENT WILL NOT BE COVERED BY OUR GUARANTEE AND/OR WARRANTY

Issue                                                                 Cause                                                             Remedy

water level is too low 

hand shower delivering insufficient water        

temperature regulation not possible                 

(only hot or cold water at time of
installation)***                                                  

temperature regulation not possible                

(only hot or cold water)                                   

*** Vigo is not responsible for pressure related issues stemming from the home's water supply. The customer should read,
understand and/or ask a certified plumber prior to installation. If these steps are not taken the product may not work at optimum

efficiency.

Trouble Shooting

                                       debris in flexible hose connection 

                               flush the line

build up of mildew or soap scum 

soak or replace hand shower

exchange thermostatic cartridge

thermostatic cartridge is defective

PSI or GPM improper 

install pressure regulator

exchange thermostatic cartridge

                                 resecure or replace supply hose(s)

thermostatic cartridge is defective 
or supply hose(s) faulty                     

TOLL FREE: (866) 591 - 7792

E-Mail:

[email protected]

www.vigoindustries.com

Содержание VG08010

Страница 1: ...1 PACKING LIST TOOLS NEEDED PANEL DIMENSIONS FITTINGS TECHNICAL DATA WALL CORNER INSTALLATION CARE AND TROUBLE SHOOTING WARRANTY MODEL VG08010 CONTENT...

Страница 2: ...1 CORNER BRACKET INSTALLATION HDWR 4SET 88074 SILICONE FREE FROM ACETIC ACID PACKING LIST 2 VALVE HOUSING 88086 THERMOSTATIC CARTRIDGE TYPE B 88011B DIVERTER CARTRIDGE 88012 VOLUME CARTRIDGE 88013 DIV...

Страница 3: ...D TO THE NEAREST 1 8 MODEL VG08010 PANEL DIMENSIONS 3 5 1 2 83 7 8 4 1 8 23 1 8 30 1 8 10 5 8 51 3 8 NOTE Dimension may vary up to 1 4 It is highly recommended to pull all dimensions off actual model...

Страница 4: ...ATA FRONT VIEW TECHNICAL DATA MIN FLOW PRESSURE 30 PSI MAX OPERATING PRESSURE 60 PSI OVERALL WATER PRESSURE IS 2 5 GALLONS HEAD SHOWER 2 0 GALLONS PER MINUTE AT 60 PSI DIVERTER 88087 88090 VOLUME CONT...

Страница 5: ...MODEL VG08010 WALL INSTALLATION 5 88074 88006...

Страница 6: ...not mix the hoses have been connected to the incorrect supplies Please disconnect the hoses reattach them to the correct supplies and test the unit before calling the Vigo Technical Service center Not...

Страница 7: ...INSTALLATION MODEL VG08010 7 Place the larger of the two corner brackets on the top portion of the wall and the smaller of the two brackets near the bottom of the wall 88074 88007G 88006 88074 88007G...

Страница 8: ...8 MODEL VG 080010 X 2 88085 84038 84040 84005 84000 88008 84001 84044 84001 84044...

Страница 9: ...necessary Regular cleaning can prevent calcification When using spray cleaner spray first onto a cloth or sponge never directly spray onto the sanitary tapware as drops could enter openings and gaps a...

Страница 10: ...er This warranty does not apply to Products that have not been installed or operated in accordance with instructions supplied by VIGO and all applicable rules regulations and legislation pertaining to...

Отзывы: