GUIDELINES FOR BASE INSTALLATION
SHOWER BASES
1) Vigo does not provide any drainage fittings
or P trap with the Vigo Brand Shower Base.
2) Important note - Please review your
specific drain manufacturer's instructions for
proper installation and follow local acceptable
plumbing code.
3) Before starting of installation it is
important that the floor and all framing be
square and level.
Installation Procedure
4) Position the base in the intended final
location and check the following details before
final installation:
(Figure 2a, 2b and Figure 2c);
Confirm dam is resting flush on the floor.
Confirm drain placement.
Confirm the top of base is level on all
sides.
Confirm the base is square in the alcove
framework.
Confirm the front inside corner is plumb
at each end. (This is critical for the proper
installation of an enclosure)
All plumbing and drainage has to be
installed before securing the shower unit
to ensure correct positioning.
The base must be positioned square in the
alcove framework.
The use of shim or filler material behind the
fastening flange at each framing member may
be required to maintain the base in the proper
position.
After the base is confirmed leveled and square in
the alcove, predrill holes that are in alignment to
the stud or framing. Secure the base in place
across the back wall first, followed by the
flanges. Using 1-1/4 inch long appropriate
fasteners. Attach the base to the framing making
sure to confirm the base remains square after
each fastener is installed until all fasteners are
installed.(Figure 3a and 3b on following page)
11