background image

3

To ensure that your installation project goes smoothly, please review these
instructions before proceeding.
Your new lavatory is designed for years of trouble-free performance.

Keep it looking new by cleaning it periodically with a soft cloth. Avoid abrasive
cleaners, steel wool and harsh chemicals.  400 grit sand paper is provided to
remove tough stains.  Run warm water over the effected areas and lightly, in a
circular pattern buff out the stain. Please do not over buff as the material will

deform in shape and may not drain properly.  Contact Vigo Industries' tech
department with any questions or concerns.

MAINTENANCE

REQUIRED TOOLS

Plumber's putty or Caulk
Caulking Gun

Tape Measure

SAFETY TIPS

Observe all local plumbing and building codes.
Risk of personal injury or product damage. Handle with care. Material can break
or chip if the product is handled carelessly.
Prior to installation, unpack the new lavatory and inspect it for damage. Return the
lavatory to its protective carton until you are ready to install it.

IMPORTANT POINTS

1.  Installation must be done by a qualified, licensed plumber . The contractor must
perform a dry fit prior to drilling holes in the counter top for the sink.

3.  All Vigo vessel bowls are hand made. You may expect variations in color,
texture and bowl symmetry. If you notice any obvious variation or defects you
should contact your retailer immediately.
4.  Though resistant to breakage, vessel sinks can break or chip when a heavy
object falls in or on them.

INSTALLATION

Installation must be done by a qualified licensed plumber.
Prior to installation please read the instructions thoroughly, confirm that all parts
are included and visually inspect the unit for any defects.
If you have any questions please contact the Vigo Technical Support
Department before proceeding with installation.

PACKAGE CONTENTS

LAVATORY

Turn off the water supply. This is done by closing the two shut-off valves
located under the lavatory. If there are no shut-off valves leading to the lavatory,
you must turn off the water at the main valve. This is usually located in the
basement, garage or near the foundation on the outside of the house. It may
also be near the water meter. Check to be sure the water is off by turning on
the faucet where you are working until the water stops flowing. If you have shut
off the main valve in a two-story house or greater, you should open the kitchen
faucet and another faucet on the same level. Water will then drain from the
entire line. This will help avoid spills. Be sure and close the faucets before you
turn on the main valve again. Disconnect the drain pipes. Take off as many
sections as possible between the lavatory and the wall or floor to facilitate

removal. Place a basin under the work area to catch any water that may still be
in the drain.

REMOVING YOUR OLD LAVATORY

ASSEMBLY

ONLY THE SINK IS PROVIDED

Make sure to use the intended style drain / pop-up. The Vigo style vessel bowl
does not have an overflow. Therefore the drain / pop-up needs to
correspond appropriately.

NOT PROVIDED

TAIL PIECE

DRAIN NUT

TO DRAIN

WASHER

DRAIN ASSEMBLY

SOFT WHITE WASHER

POP UP TOP

INTERNAL BRASS PIECE (POP UP MECHANISM)

1. Please inspect your working surface, making sure it is level and clean.

2. Determine the layout for the sink you desire. It is important to fully "dry" position
the sink with your faucet purchase on the countertop. Things to include, but are not
limited to;

desired position.

DO NOT OVER TIGHTEN THE DRAIN

!

POP UP DRAIN

RUBBER WASHER

TAIL PIECE

DRAIN NUT

SOFT WHITE WASHER

POP UP DRAIN TOP

RUBBER WASHER

SINK

COUNTERTOP

TAIL PIECE NUT

COUNTERTOP

INTERNAL BRASS PIECE
(POP UP MECHANISM)

(with stand installed)

WHITE PLASTIC WASHER

WHITE PLASTIC WASHER

Содержание VG04013

Страница 1: ...INK SINK HOLE LENGTH WIDTH HEIGHT DIAMETER VG04013 18 1 8 14 5 8 4 7 8 1 3 4 DIMENSIONS MODEL VG04013 FEATURES PACKING LIST TOLL FREE 866 591 7792 E Mail techmail vigoindustries com www vigoindustries com For warranty purposes contact our toll free number 18 1 8 4 7 8 TM ...

Страница 2: ...VG04013 THE MEASUREMENTS IN INCHES ARE ROUNDED TO THE NEAREST 1 8 TOP VIEW FRONT VIEW NOTE MATERIAL DIMENSIONS MAY VARY UP TO 3 8 1 3 4 18 1 8 14 5 8 14 1 8 17 1 2 18 1 8 4 7 8 15 5 8 11 3 4 15 5 8 5 8 3 8 2 ...

Страница 3: ...he Vigo Technical Support Department before proceeding with installation PACKAGE CONTENTS LAVATORY Turn off the water supply This is done by closing the two shut off valves located under the lavatory If there are no shut off valves leading to the lavatory you must turn off the water at the main valve This is usually located in the basement garage or near the foundation on the outside of the house ...

Страница 4: ...s installed by fully insured licensed professionals Vigo strongly recommends that such licensed professionals have experience in the installation of bathroom and kitchen products Installation of certain products including without limitation glass products i e shower doors and glass sinks by an inexperienced person may result in glass breakage and consequently cause personal injury or death VIGO is...

Страница 5: ...Lavabo vasque en pierre mate Ouverture du drain standard Surface non poreuse Fini mat Installation sur un comptoir LISTE DES ARTICLES Vasque Sans frais 866 591 7792 Courriel techmail vigoindustries com www vigoindustries com Pour toute question concernant la garantie composez 18 1 8 4 7 8 ...

Страница 6: ...VUE DE DESSUS VUE DE FACE 15 5 8 11 3 4 15 5 8 5 8 3 8 1 3 4 18 1 8 14 5 8 14 1 8 17 1 2 18 1 8 4 7 8 2 ...

Страница 7: ... plus grand nombre de sections de drain possibles entre le lavabo et le mur ou le sol ASSEMBLAGE SEUL LE LAVABO EST FOURNI propre dans la position voulue 3 Marquez et percez un trou de 0 1 3 4 sur le comptoir afin de placer le drain COMPTOIR COMPTOIR NON INCLUS VERS LE DRAIN RONDELLE ENSEMBLE DE DRAIN SOUPLE BLANCHE DESSUS DE LA BONDE NE SERREZ PAS TROP LE DRAIN DRAIN DE LA BONDE RONDELLE DE CAOUT...

Страница 8: ... Limitations l installation de certains produits y compris sans toutefois s y limiter les produits en verre portes de douches et lavabos en verre sont susceptibles de les briser et par SAUF DISPOSITION CONTRAIRE CI DESSUS VIGO NE FAIT AUCUNE GARANTIE EXPRESSE OU IMPLICITE Y COMPRIS DE VALEUR le constructeur Limitations commerciales Service de garantie ...

Страница 9: ...edra mate Modelo VG04013 MODELO ARGO ANCHO ALTO NRO DEL LAVABO DEL LAVABO DEL LAVABO DEL ORIFICIO VG04013 18 1 8 14 5 8 4 7 8 1 3 4 DIMENSIONES MODELO VG04013 CONTENIDOS DEL PAQUETE techmail vigoindustries com www vigoindustries com 18 1 8 4 7 8 ...

Страница 10: ...MODELO VG04013 VISTA SUPERIOR VISTA FRONTAL 15 5 8 11 3 4 15 5 8 5 8 3 8 LAS DIMENSIONES DEL MATERIAL PUEDEN VARIAR HASTA 3 8 1 3 4 18 1 8 14 5 8 14 1 8 17 1 2 18 1 8 4 7 8 2 ...

Страница 11: ...pueden quebrarse o picarse cuando caen objetos pesados dentro de ellos o sobre ellos CONTENIDO DEL PAQUETE LAVABO MONTAJE y limpia posicionar el lavabo por completo en seco con el grifo comprado en la encimera Alguna de las cosas a considerar entre otras TUERCA DE ARANDELA BLANCA PARTE SUPERIOR DEL ARANDELA BLANCA LAVABO ENCIMERA PIEZA INTERNA DE BRONCE EMERGENTE ARANDELA DE CAUCHO NO INCLUIDO TUE...

Страница 12: ...inales para el propietario o usuario final originales y no es transferible a propietarios posteriores Limitaciones aplicables sobre dichas instalaciones productos de vidrio es decir puertas de duchas y lavabos de vidrio por parte de personas sin experiencia puede provocar ruptura del vidrio y por ende lesiones personales o la muerte Producto Limitaciones comerciales estado o la provincia ...

Страница 13: ...struction Ceramic disk cartridge Single lever faucet Wall mount installation Finish resist corrosion and tarnishing PACKING LIST Faucet Assembly Allen Key Spout Cover for spout Mixer Handle Cover for handle Washer 7 1 8 4 1 2 NOTE All faucets are compliant to CEC 2016 regulations If you have inquiries about your water flow please email techmail vigoindustries com ...

Страница 14: ...VG05001 THE MEASUREMENTS IN INCHES ARE ROUNDED TO THE NEAREST 1 8 2 3 8 4 1 2 7 1 8 7 8 5 1 4 4 1 4 9 2 TOP VIEW FRONT VIEW SIDE VIEW 2 ...

Страница 15: ...e with altering the product post sale and highly advises that the client only install the product that meets the needs of their local plumbing code Flow rate with installed aerator 1 2 gpm Flow rate with aerator provided in box 1 5 gpm FLOW RATE REGULATIONS Twist open the aerator cover counterclockwise to remove the aerator You will find an aerator installed here Simply remove the 1 2 gpm aerator ...

Страница 16: ...d and hot water lines and open the hot and cold knobs on the old faucet to release build up pressure When installing your new faucet turn the connector nuts finger tight then use one wrench to anchor the fitting and a second wrench to tighten the nut one additional turn Connections that are too tight will reduce the integrity of the system Wrap all threaded connections with Teflon tape available a...

Страница 17: ... is secure Make sure to use pipe tape 2 B Remove supply lines and flush lines 2 A Remove aerator and soak clean with a non abrasive agent i e half hot water and half vinegar 1 B Contact Vigo Technical Support for replacement 1 A Remove cartridge from housing wash thoroughly with hot water and reseat in housing 3 B Remove supply line and check the status of the washer If torn washer must be replace...

Страница 18: ...h access is not available all expenses to provide said access will be the responsibility of the owner This warranty does not apply to Products that have not been installed or operated in accordance with instructions supplied by VIGO and all applicable rules regulations and legislation pertaining to such installations This warranty does not apply unless the VIGO Product is installed by fully insure...

Страница 19: ... DU JET VG05001 4 1 2 7 1 8 DIMENSIONS Installation murale et en angle LISTE DES ARTICLES Ensemble de robinet Jet Cache de jet Mitigeur Rondelle de la CEC de 2016 Si vous avez des questions au sujet de votre 7 1 8 4 1 2 ...

Страница 20: ...VG05001 2 3 8 4 1 2 7 1 8 7 8 5 1 4 4 1 4 9 2 VUE DE DESSUS VUE DE FACE 2 ...

Страница 21: ...3 responsable des modifications et de la touche qui peut venir avec la modification du poste de vente de produits et horaire Bec Bec ...

Страница 22: ...a laine d acier et raccords dans le sens des aiguilles d une montre sont pas tous inclus Cependant ils sont disponibles dans tout magasin de plomberie Pince multiple Mastic de plombier Ruban pour tuyau EAU FROIDE JET EAU CHAUDE RONDELLE ENTRETIEN POINTS IMPORTANTS INSTALLATION ASSEMBLAGE CONTENU DE L EMBALLAGE L ANCIEN ROBINET ET LES ANCIENS FLEXIBLES NETTOYEZ LA SURFACE DU LAVABO EN VUE DE L INST...

Страница 23: ...nts de raccordement 3 A Fuite du flexible au niveau du point de raccordement 1 B Contactez le service de soutien technique de Vigo pour remplacer la cartouche l eau chaude et replacez la cartouche dans son logement pas de fuites perpendiculaire au comptoir cartouche 2 C Retirez les axes en cuivre et rincez nettoyez les CH BN ARB CH BN ARB CH BN ARB Valve Logement W 68090 ...

Страница 24: ...tructeur un tiers Limitations directement ou indirectement produit notamment mais sans s y limiter de les briser et de provoquer des blessures voire la mort SAUF DISPOSITION CONTRAIRE CI DESSUS VIGO NE FAIT AUCUNE GARANTIE EXPRESSE OU IMPLICITE Y COMPRIS DE VALEUR MARCHANDE constructeur Limitations commerciales Service de garantie ...

Страница 25: ...ES MODELO VG05001 CONTENIDOS DEL PAQUETE Juego de grifo Llave Allen Boca Cubierta para la boca Mezclador Llave Cubierta para la llave Arandela NOTA Todos los grifos cumplen con CEC 2016 regulaciones Si usted tiene preguntas acerca de su flujo de agua por favor escriba techmail vigoindustries com 7 1 8 4 1 2 ...

Страница 26: ...VG05001 2 3 8 4 1 2 7 1 8 7 8 5 1 4 4 1 4 9 2 VISTA SUPERIOR VISTA FRONTAL VISTA LATERAL 2 ...

Страница 27: ... en el cuadro 1 5 gpm NORMAS DE CAUDAL Giro abra la tapa del aireador hacia la izquierda para quitar Basta con quitar el aireador 1 2 gpm y reemplazarlo con el aireador 1 5 gpm siempre Vuelva a colocar la cubierta del 1 2gpm aireador 1 5gpm aireador Cubierta aireador Cubierta aireador ...

Страница 28: ...odos los recursos necesarios para instalar su Llave inglesa Pinzas pico de loro Destornilladores Phillips y para tornillos de rosca cuadrada 5 CONECTE LA LLAVE CALIENTE BOCA AGUA CALIENTE LLAVE ARANDELA MANTENIMIENTO HERRAMIENTAS NECESARIAS PUNTOS IMPORTANTES CONSEJOS DE SEGURIDAD MONTAJE CONTENIDO DEL PAQUETE 1 CIERRE EL SUMINISTRO DEL AGUA QUITE EL GRIFO VIEJO Y LAS MANGUERAS FLEXIBLES LIMPIE LA...

Страница 29: ...l grifo 1 A Cartucho no ajustado 1 B Cartucho defectuoso 2 A Aireadores sucios 3 B Arandela defectuosa 4 Los dispositivos de ensamblaje se aflojaron 3 A Ajuste las mangueras Si eso no resuelve el problema no abrasivo es decir mitad agua caliente mitad vinagre 4 Desde debajo de la encimera utilice una llave inglesa para 5 Afloje la llave al tornillo que conecta la llave con el cartucho Con una llav...

Страница 30: ...autorizado de VIGO y durante toda la vida del propietario o usuario final originales VIGO Limitaciones aplicables sobre dichas instalaciones otros productos de vidrio es decir puertas de duchas y lavabos de vidrio por parte de personas sin experiencia puede provocar fallos en el producto incluidos entre otros el Producto Limitaciones comerciales ...

Отзывы: