Application Drawing
Vi2408A
Coax Ethernet Extender’s Installation Manual
DO NOT OPEN
RISK OF ELECTRIC SHOCK
CAUTION
CAUTION:
TO REDUCE THE RISK OF ELECTRICAL SHOCK,
DO NOT REMOVE COVER. NO USER SERVICEABLE
PARTS INSIDE. REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
IP Camera-end Installation
The Smart Choice for Transmission Solutions
www.vigitron.com
The MaxiiCopper Model Vi2408Ais a revolutionary data transmission device
that extend full-duplex High-Speed Ethernet over existing coaxial
infrastructures. it transmits Ethernet 10BaseT signal up to 5,000 ft. (1,524m)
and 100BaseT up to 1,800 ft. (546m). When using Pass Through PoE (PTP
™), It extend 10BaseT up to 3,000 ft. (914m) and 100BaseT up to 1,800 ft.
(546m). It employs MaxiiCopper, an innovative and unique Ethernet
extension technology, that is designed to take full advantage of
high-bandwidth coaxcial cables and maintain a full-duplex 10 or 100 Mb/s
Ethernet connection up to the maximum range with minimum transmission
error and latency. Multiple remote network devices such as Mega-pixel IP
cameras or VoIP can be connected to a central LAN switching fabric with
ease. Its dual-rate capability provides an easy way to balance the best
possible network throughput and long-reach distance design.
These hubs need to be deployed along with Vi2401A on the remote end of
each coaxial cable. They are equipped with LEDs to provide link status and
configured data rate for each port. They are completely transparent to the
corporate IP network and higher layer protocols and require no IP
programming or other configurations.
The Vi2408A is ideal for medium to large scale IT networking or digital
CCTV projects.
Important Safety Warning
- Use a Vi2401A single port extender for the camera side transmission.
- Set the Master/Slave dip switch to “Master” mode.
- Connect the external 12VDC power supply to the power connector of the
Vi2401A. An optional power adapter connector can be provided to simplify
connection. If no local power supply is present the Vi2401A will use POE.
- Connect the IP camera’s RJ45 connector to the 10/100BaseT Ethernet
port of Vi2401A using a standard Cat5/6 patch cable of maximum 330 feet
(100 m) in length.
- Connect one end of the long coax cable to the BNC connector of Vi2401A.
The link LED on the 10/100 connector should be “ON” to indicate proper
connection between the camera and Vi2401A.
Ethernet Switch/NVR-end Installation
- Connect the chassis ground screw to a solid earth ground.
- Connect the RJ45 connector of the Ethernet switch to the 10/100BaseT
Ethernet port of Vi2408A using a standard Cat5/6 cable of maximum 328
feet (100m) in length.
- Connect long coax cables to the BNC connectors of Vi2408A.
- Connect the 12VDC power supply to the power connector of Vi2408A.
The link LED on the 10/100 Ethernet connectors should be “ON” to indicate
proper connection between the switch and Ethernet ports of Vi2408A. While
the Link LED, Orange for 100BaseT and Green for 10BaseT, on the coax
side, in a steady state will indicate confirmed connection between extenders.
- Read and keep these instructions.
- Heed all warnings.
- Follow all instructions.
- Do not use this apparatus near water.
- Clean only with a dry cloth.
- Install in accordance with the manufacturer’s instructions.
- This installation should be made by a qualified service person and should conform to all local
codes.
- DO NOT bundle UTP or Coax signals in the same conduit as high-voltage wiring.
- To reduce the risk of fire or electrical shock, do not expose these products to rain, moisture,
dripping or splashing.
- No objects filled with liquids, such as vases, shall be placed on Vigitron equipment.
- DO NOT install the unit in a place where the operating ambient temperature exceeds 75°C.
- Make sure that the external power supply output voltage is in the recommended range.
- Do not install near any heat sources such as radiators, heat registers, stoves or other
apparatus (including DVRs) that produce heat.
- Protect the power cord from being walked on or pinched particularly at power source,
convenience receptacles, and the point where they exit from the apparatus.
- Only use attachments/accessories specified by the manufacturer.
- Unplug this apparatus during lightning storms or when unused for long periods of time.
- Refer all servicing to qualified service personnel. Servicing is required when the apparatus
has been damaged in any way, such as when a power supply cord or plug is damaged, liquid
has been spilled, objects have fallen inside the apparatus, the apparatus has been exposed
to rain or moisture, does not operate normally, or has been dropped.
- The main plug is used as the disconnect device and shall remain readily operable.
WARNING! - To reduce the risk of fire or electric shock, do not expose
this apparatus to rain or moisture. This apparatus shall not be exposed to
dripping or splashing and no objects filled with liquids, such as vases shall
be placed on the apparatus.
WARNING! - This apparatus is a Class I product. This product must
be connected to a mains socket outlet thru an AC to DC Power supply.
WARNING! - The mains plug is used as the disconnect device and
shall remain readily operable.
Max
ii
Copper
TM
Connecting Multiple PoE Cameras over Extended Coax Cables
Network Switch
Vi2408A
Data +
PoE
328 ft. (100m)
Data +
PoE
328 ft. (100m)
Data +
PoE
328 ft. (100m)
Data +
PoE
328 ft. (100m)
PoE Cameras
Vi2401A
Vi2401A
Vi2400WP
Data +
PoE
Extended Coax
Data +
PoE
Extended Coax
Data +
PoE
Extended Coax
Data +
PoE
Extended Coax
Vi2400A
Data +
PoE
328 ft. (100m)