background image

 

 

Application Drawing 

Vi2804 4-Port Extended Ethernet Switch Installation Manual

DO NOT OPEN

RISK OF ELECTRIC SHOCK

CAUTION

CAUTION: 

TO REDUCE THE RISK OF ELECTRICAL SHOCK,

                   DO NOT REMOVE COVER. NO USER SERVICEABLE

                   PARTS INSIDE. REFER SERVICING TO QUALIFIED

                   SERVICE PERSONNEL.

IP Camera-end Installation

The Smart Choice for Transmission Solutions                       

www.vigitron.com

The MaxiiCollector Model Vi2804 is a revolutionary four port switch that 

extends full-duplex High-Speed Ethernet over extended distance UTP and 

Coax infrastructures. 
Typical extended distances can be achieved up to 3,000 feet (909 m) over 

UTP and up to 5,000 feet (1,524 m) over Coax.are: 
The Vi2804 employs MaxiiCopper innovative and unique Ethernet extension 

technology that is designed to take full advantage of high-bandwidth 

networking cables and maintain a full-duplex 10 or 100 Mb/s Ethernet 

connection up to the maximum range with minimum transmission error and 

latency. The Vi2804 can connect multiple remote network devices such as 

Mega-pixel IP cameras or VoIP to a central LAN switching fabric with ease. 

Its dual-rate capability feature provides an easy way to balance the best 

possible network throughput and extended-reach distance design. 
The Vi2804 is a transceiver device and needs to be deployed in conjunction 

with another Ethernet at the other end of extended UTP or Coax cable as 

master and slave devices. A dip switch sets the data rate between the 

remote and local location. It is equipped with LEDs to provide link status and 

configured data rate. No IP setting or configurations are required and it is 

completely transparent to the corporate IP network and higher layer 

protocols. The UTP or Coax cable needs to be point to point without any 

branches. 
The four 10/100 Ethernet inputs can be routed from four individual devices, 

each with their own IP address. The switching component is 

pre-programmed and provides for 802.1p QoS priority queuing, port based 

VLAN, MAC address up to 2K, full and half duplex operation compliant to 

802.3x, and automatic address learning and aging. 
Fixed switch settings provides maximum network security.

Important Safety Warning

-Set S1 (10/100 BaseT) dip switch to the appropriate rate based on the 

required maximum data rate and maximum distance. 

-Set S2 (Master/Slave) dip switch to “Master” mode. 

-Set S3 (1/4 pair) dip switch based on the desired number of pairs. 

- Connect the external 12VDC power supply to the power connector of the 

  Vi2804. An optional power adapter can be provided to simplify installation

  If no local power supply is present the Vi2804 will use PoE.

- Connect up to 4 IP camera’s to the standard Ethernet ports of Vi2804 

using a standard Cat5/6 patch cables of maximum 330 feet (100 m) in 

length. These ports will automatically sense the correct port speed based 

on the input signal. The link LED on the 10/100 connector should be “ON” 

to indicate proper connection between the camera and Vi2804. 
Note: While each standard Ethernet port can operate at either 10 or 100 

Mbps, the extended port is 100Mbps max. The recommended total 

bandwidth limitation should not exceed 54Mbps and is above the upper 

limit for transmitting four cameras. 
Extended UTP connection: 

-Connect one end of the extended UTP cable to the RJ45 connector of 

Vi2804. The link LED on the 10/100 connector should be “ON” to indicate 

proper connection between the camera and Vi2804. 
Extended  Coax connection: 

- Connect one end of the extended Coax cable to the Coax connector of 

Vi2804. The link LED on the 10/100 connector should be “ON” to indicate 

proper connection between the camera and Vi2804. 

Ethernet Switch/NVR-end Installation

Ethernet Switch/NVR-end Installation 

-Set the Master/Slave dip switch to “Slave” mode. 

-Set 10/100 and 1/4 pair dip switches the same as the camera-end setting. 

- Read and keep these instructions.

- Heed all warnings.

- Follow all instructions.

- Do not use this apparatus near water.

- Clean only with a dry cloth.

- Install in accordance with the manufacturer’s instructions.

- This installation should be made by a qualified service person and should conform to all local 

  codes.

- DO NOT bundle UTP or Coax signals in the same conduit as high-voltage wiring.

- To reduce the risk of fire or electrical shock, do not expose these products to rain, moisture,

  dripping or splashing.

- No objects filled with liquids, such as vases, shall be placed on Vigitron equipment.

- DO NOT install the unit in a place where the operating ambient temperature exceeds 75°C or  

   is below - 40°C.

- Make sure that the external power supply output voltage is in the recommended range. 

- Do not install near any heat sources such as radiators, heat registers, stoves or other 

  apparatus (including DVRs) that produce heat.

- Protect the power cord from being walked on or pinched particularly at power source, 

  convenience receptacles, and the point where they exit from the apparatus.

- Only use attachments/accessories specified by the manufacturer.

- Unplug this apparatus during lightning storms or when unused for long periods of time.

- Refer all servicing to qualified service personnel. Servicing is required when the apparatus 

  has been damaged in any way, such as when a power supply cord or plug is damaged, liquid

  has been spilled, objects have fallen inside the apparatus, the apparatus has been exposed 

  to rain or moisture, does not operate normally, or has been dropped.

- The main plug is used as the disconnect device and shall remain readily operable.

         WARNING! - To reduce the risk of fire or electric shock, do not expose 

this apparatus to rain or moisture. This apparatus shall not be exposed to 

dripping or splashing and no objects filled with liquids, such as vases shall 

be placed on the apparatus.
         WARNING! - This apparatus is a Class I product. This product must 

be connected to a mains socket outlet thru an AC to DC Power supply.
         WARNING! - The mains plug is used as the disconnect device and 

shall remain readily operable. 

 Ethernet Extenders

MaxiiCollector

Up to 3,000 ft. (909 m) Cat-5

Cat-5

(100 m)

Data

NVR

PoE Switch

Vi2316

IP Cameras

Up to 100m Cat-5

Up to 3,000 ft. (909) m Cat-5 or 

5,000 ft. (1,524 m) Coax

Cat-5

(100 m)

Data

NVR

PoE Switch

Vi2416

IP Cameras

Up to 100m Cat-5

Extended Coax Application:

Extended UTP Application:

Up to 5,000 ft. (1,515 m) Coax

NVRs

IP Cameras

Up to 100m Cat-5

Extended UTP or Coax Application:

Up to 100m Cat-5