Front Service Slimline & 15U Cabinet
A rear service Slimline cabinet can be converted to front
service format by unclipping the display board(s) from
the plastic standoffs on the gear plate and moving them
to the metal standoff mounts on the front panel, as
shown in Figures 18 and 19.
The excess length of the LM0335 loom can be folded
and clipped in place on the front panel.
A front service index will also require fitting (see next
section).
The 15U cabinet is front service only.
Figure 19
– Single Zone Display on front panel
(Front Service format)
A second front service zone display
board (part number FP1002) can be
fitted, as shown in Figure 19.
Note that the FRC loom from the
LCD/keyboard must be moved from
the first display board to the second
display board, and the second
display board connected to the first
display board with the LM0291 FRC
loom provided with the zone display
kit (FP1002).
Figure 19
– Double Zone Displays on front panel (Front Service format)
The 15U cabinet can optionally be fitted with up to two 4U doors (ME0457) which can each hold five of these
zone display modules, giving a total of 191 zones of indication. One LM0092 cable will be needed to run from the
LCD/keyboard to the highest number zone LED board on the ME0457, and 1 x LM0056 will be needed to
connect LED displays on one ME0457 to either the next or to the
MX1
4U inner door. An additional LM0056 will
be needed when the second ME0457 is fitted. Drawing 1982-88 shows example arrangements.
ZONE DISPLAY LABELLING
Front Service Slimline & 15U Cabinet
Zone displays mounted on the front panel can be labelled with strips of card slipped through the slot in the panel
above each display. A pre-printed set of labels on grey card is available as LB0600 (5 strips per sheet). One sheet
is supplied with each
MX1
.
Alternatively, a template file (LT0369) is available. The required text is entered into this template document, which is
then printed at 100% scaling onto suitable material (grey card).
The optional Slimline cabinet front service index (part number FA2417) is fastened to the door of the cabinet with
four hex head screws supplied with the
MX1
. The engraving on the front service index needs to match the wording
of the zone indicator labelling.
PA1057 / PA1010
LCD/Keyboard PCB
LM
0335
Zone
Display Board
1
-
Common
Indicators and
Zones
s
1
-
15
J
2
FR
OM
P
R
E
V
IOU
S
TO
N
E
X
T
FP1002
LM
0291
J
2
Zone Display
Board 2
-
Zones 16-31
(FP1002)
FR
OM
P
R
E
V
IOU
S
TO
N
E
X
T
(FP1002)
FR
OM
P
R
E
V
IOU
S
TO
N
E
X
T
LM0335
Zone Display
Board 1
-
Common
Indicators and
Zones 1-15
PA1057 / PA1010