6
Suggestions
The installation and maintenance of your Guardian Humidification System will directly affect its
Performance. Here are some factors to consider:
•
Do not block the airflow of the humidifier fan. Shelves or boxes of cigars should be at least 4” above
the fan.
•
Do not block the sensor by stacking boxes or other impediments in front of it.
•
Keep the water Reservoir and Wicking Filter in the humidifier clean by servicing at least every four
months.
•
Avoid frequent opening of your cabinet’s door. If the humidor is used for commercial environments,
nighttime recovery will be crucial for maintaining an optimum environment.
Trouble Shooting Answers
Cabinet appears not to maintain desired humidity level:
•
Check the set-point adjustment by depressing the far-left key on the control panel. If the set point is
not at your desired relative humidity level, reset by following the “Adjusting the Humidity” instruction
previously mentioned.
•
Check the seal of the door and drawers of your cabinet. The System may not be able to sustain
adequate humidity levels in a cabinet that is not airtight.
•
Check the water level in the Reservoir. If it is empty, the red LED should be lit. If not, carefully
fill
your Reservoir to approximately 1" below the overflow hole.
IMPORTANT:
DO NOT POUR WATER ON THE FAN.
DO NOT OVERFILL THE RESERVOIR, AS OVERFILLING WILL CAUSE DAMAGE TO YOUR
CABINET!
DO
NOT
POUR
WATER
ON
THE
FAN
THIS
CAN
CAUSE
DAMAGE
TO
THE
ELECTRONICS.
DO
NOT
MOVE
CABINET
WITH
WATER
IN
IT.
•
Be certain that the fan and airflow intake are clear of any obstructions which can impede air
circulation.
•
Verify that the humidity wick is vertically positioned inside of the Reservoir.
Cigars are too moist or too dry:
•
Your humidity set point is too high or too low. Remember, add 2% to the number you set on the
display for the average humidity level. It is recommended that you start your Guardian Humidification
System at the pre-set level of 67%. This will maintain an interior humidity level of between 66% and
68%.