Fixing the unit for LPG detection
TrueSafe cloud Detector has unique patented enclosure design. After selecting the right
location, fix the unit on the wall with the wall mounting plugs and screws provided with the
unit.
The unit can be installed either as shown in Fig 3 or as in Fig 4.
1.
It can be mounted on the front door of kitchen cabinet of the LPG Cylinder. This will
enable detection of gas leak from the cylinder as well as the gas stove.
Figure 3
Note
: If True Safe is mounted on the door as shown above, power supply wire should be properly
routed so that it does not get pinched in the hinges while closing the door.
2.
If it is mounted behind gas cylinder, the cabinet for the gas must have grills in order to
detect gas leak from the gas stove also. Please refer the following diagram.
Figure 4
Locations to be avoided for installing True Safe
Very near to exhaust fan
By the side of a door or window
In an enclosed space: Many times, LPG detector is mounted on the wall, behind the
LPG cylinder, under the kitchen platform with the door without grill. This creates
confined space around the detector and cylinder, regulator and tube connecting it. In
such case, detector will effectively detect LPG leaks happening only in this confined
space. If there is LPG leak from the gas stove because of either faulty connection to the
tube or by leaving gas burner ON
Содержание TrueSafe Gas Cloud