WIRING (only 24V~ inputs)
1. On the back of the monitor, loosen the thumb screws and lower the access panel.
2. Attach the leads from the power supply (supplied) to the left and right connectors.
WARNING: Do not connect a ground to the center post.
Please be careful of voltage polarity.
3. When finished, secure the access panel.
Table A shows the recommended maximum wiring distances (transformer to load),
and are calculated with a 10-percent voltage drop.
Recommended Wiring Distances
Inch
Wire
18AWG
16AWG
14AWG
23
”
150 ft
(45 m)
240 ft
(73 m)
300 ft
(91 m)
27
”
60 ft
(18 m)
120 ft
(36 m)
150 ft
(45 m)
32
”
30 ft
(9 m)
30 ft
(9m)
90 ft
(27 m)
- 6 -