54
Indicators
Light
Status & Description
Power events
Blue
Flashing
Off
Off
Stand-by mode
Blue
Off
Off
Powering up
Blue
Off
Off
Normal operation
Blue
Flashing
Off
Off
Normal power-down cooling (3 sec)
Red
Off
Off
Downloading
Blue
Blue
Blue
Burn in off
Lamp events
Blue
Flashing
Off
Red
First Lamp-Lit error cooling (60 sec)
Off
Off
Red
Lamp error in normal operation (30 sec)
Blue
Off
Red
CW start fail (30 sec)
Thermal events
Off
Red
Off
Fan 1 error (the actual fan speed is +25% outside the
desired speed.)
Off
Red
Red
Fan 2 error (the actual fan speed is +25% outside the
desired speed.)
Off
Red
Blue
Fan 3 error (the actual fan speed is +25% outside the
desired speed.)
Off
Red
Purple
Fan 4 error (the actual fan speed is +25% outside the
desired speed.)
Red
Red
Red
Thermal sensor 1 open error (the remote diode has an
open-circuit condition.)
Red
Red
Blue
Thermal sensor 2 open error (the remote diode has an
open-circuit condition.)
Blue
Red
Red
Thermal sensor 1 short error (the remote diode has an
short-circuit condition.)
Off
Red
Blue
Thermal sensor 2 short error (the remote diode has an
short-circuit condition.)
Purple
Red
Red
Temperature 1 error (over limited temperature)
Purple
Red
Blue
Temperature 2 error (over limited temperature)
Off
Blue
Red
Fan IC #1 I2C connection error
Содержание PRO7827HD
Страница 65: ...58 Tripod mount installation 13 00 27 13 Unit mm ...