45
Get function table:
Get Function Length
ID
Command
Type
Command
Value Range
Comments
Code (ASCII)
Code (Hex)
(Three ASCII bytes)
Get-Contrast
8
g
a
61
000 ~ 100
Gets Contrast value
Get-Brightness
8
g
b
62
000 ~ 100
Gets Brightness value
Get-Sharpness
8
g
c
63
000 ~ 100
Gets Sharpness value
Get-Color
8
g
d
64
000 ~ 100
Gets Color value
Get-Tint
8
g
e
65
000 ~ 100
Gets Tint value
Get-Volume
8
g
f
66
000 ~ 100
Gets Volume value
Get-Mute
8
g
g
67
000: OFF (unmuted)
001: ON (muted)
Gets Mute ON/OFF
status
Get-Input select
8
g
j
6A
000~
See Set-function table
Get-Power
status : ON/
STBY
8
g
l
6C
000: STBY
001: ON
Get-Remote
control
8
g
n
6E
000 : Disable
001 : Enable
002 : Pass through
Get-Power Lock
8
g
o
6F
000 : Unlock
001 : Lock
Get-Button Lock
8
g
p
70
000 : Unlock
001 : Lock
Get-Menu Lock
8
g
q
71
000 : Unlock
001 : Lock
Get-Tiling Mode
8
g
v
76
000: OFF
001: ON
(for DS)
Get-Tiling
Compensation
8
g
w
77
000: OFF
001: ON
(for DS)
Bezel width
compensation
Get-Tiling H by V
monitors
8
g
x
78
01x~09x: H monitors
0x1~0x9: V monitors
(for DS)
1. 2
nd
digital for H
monitors
2. 3
rd
digital for V
monitors
Get-Tiling
position
8
g
y
79
000: OFF
001~025
(for DS)
Copy the screen of
Position# to identified
display
Get-ACK
8
g
z
7A
000
This command is
used to test the
communication link.
Get-Thermal
8
g
0
30
000~100:
0~+100 deg C
-01~-99:
-1~-99 deg C
For specific models
only
Get-Power on/
off log
8
g
1
31
000
(See below note)
For specific models
only
Get-Date
8
g
2
32
000
(See the Set-Date
command)
For specific models
only
Get- Time
8
g
3
33
000
(See the Set-Time
command)
For specific models
only