Commercial Display RS-232 Protocol
Revision 1.x
________________________________________________________________
May 28, 2007
3 / 16
Commercial Display RS-232 Protocol
TV ID
Identification for each of TV
Command
Type
Identify command type,
“s” (0x73h) : Set Command
“g” (0x67h) : Get Command
“r” (0x72h) : Reply Command
“p” (0x70h) : RCU Pass-through
“+” (0x2Bh) : Valid command Reply
“-“ (0x2Dh) : Invalid command Reply
Command:
Function command code: One byte ASCII code
Value[1~3]:
Three bytes ASCII that defines the value
CR
0x0D
3.2
Set-Function Listing
The PC can control the LCD Monitor for specific actions. The Set-Function command allows you to
control the LCD monitor behavior in a remote sit through the RS232 port. The Set-Function packet
format consists of 11 bytes.
Set-Function description:
Length:
Total Byte of Message excluding “CR”
TV ID
Identification for each of TV
If we want to set all TV settings, TV ID can use “
99
” to achieve, and
it will not have
Reply
command on this function.
Command
Type
Identify command type,
“s” (0x73h) : Set Command
Command:
Function command code: One byte ASCII code
Value[1~3]:
Three bytes ASCII that defines the value
CR
0x0D
Set-Function format
Send: (Command Type=”s”)
Name
Length
ID
Command
Type
Command
Value1
Value2
Value3
CR
Byte
Count
1 Byte
2 Byte
1 Byte
1 Byte
1 Byte
1 Byte
1 Byte
1 Byte
Bytes
order
1
2~3
4
5
6
7
8
9
Reply: (Command Type=”+” or “-”)
Name
Length
ID
Command
Type
CR
Byte
Count
1 Byte
2 Byte
1 Byte
1 Byte
Bytes
order
1
2~3
4
5
Example1: Set Brightness as 76 for TV-02 and this command is valid
Send (Hex Format)
Name
Length
ID
Command
Type
Command
Value1
Value2
Value3
CR
Hex
0x38
0x30
0x32
0x73
0x24
0x30
0x37
0x36
0x0D