3.4 TCP control
21.
For Viewpro gimbal cameras with Ethernet output, the default IP
address is: 192.168.2.119, control port: 2000. You can send the
corresponding protocol to realize TCP control after connecting.
The TCP control protocol is [Frame header: EB + command ID: 90 +
data body (serial port protocol) + Checksum (CS = body checksum,
checksum is calculated as a sum of all bytes of data body modulo
256)]. Or directly use UI Viewlink to control after TCP connection.
S.Bus control mode: default S.Bus signal channel 9-15 to control
gimbal camera functions (the function of channel is consistent with
corresponding channel in PWM function description)
TTL control and S.bus control cannot coexist at the
same time for standard version. The default control is
TTL if no requirement. The user can set to S.bus control
if needed (please contact with our technical support for
the setting instruction.)
User can set the channels by setting serial command
according to the actual requirement. The S.Bus channel
position can be arranged in any sequence within
channel 1-15 to connect with the flight controller or
remote control.
Channel 9: Yaw Control
Channel 10: Pitch Control
Channel 11: Mode Control
Channel 12: Zoom Control
Channel 13: Focus Control
Channel 14: Pic/Rec Control
Channel 15: Multi Backup