background image

 

 

 

CAUTION

 

The power supply cord is used as the main disconnect device, ensure that the socket-outlet is 

located/installed near the equipment and is easily accessible. 

ATTENTION

Le cordon d`alimentation est utillsé comme interrupteur général. La prise de courant doit être 

située ou installée à proximité du matériel et être facile d`accès

 

 

 

 NEVER REMOVE THE BACK COVER 

Removal of the back cover should be carried out only by qualified personnel. 

 DO NOT USE IN HOSTILE ENVIRONMENTS 

To prevent shock or fire hazard, do not expose the unit to rain or moisture. 

This unit is designed to be used in the office or home. Do not subject the unit to vibrations, 

dust of corrosive gases. 

 KEEP IN A WELL VENTILATED PLACE 

Ventilation holes are provided on the cabinet to prevent the temperature from rising. 

Do not cover the unit or place anything on the top of unit. 

 AVOID HEAT 

Avoid placing the unit in direct sunshine or near a heating appliance. 

 TO ELIMINATE EYE FATIGUE 

Do not use the unit against a bright back ground and where sunlight or other light sources will 

shine directly on the monitor. 

 BE CAREFUL OF HEAVY OBJECT 

Neither the monitor itself nor any other heavy object should rest on the power cord. 

Damage to a power cord can cause fire or electrical shock. 

 

 

 

- 4 -

 

 

 

Содержание VZ-185RCR

Страница 1: ...18 5 INCH RACK TFT LED MONITOR USER MANUAL Please read this manual thoroughly before use and keep it handy for future reference...

Страница 2: ......

Страница 3: ...TATEMENT 5 CONNECTING WITH EXTERNAL EQUIPMENT 6 CONTROLS AND FUNCTIONS 7 12 MOUNTING GUIDE 13 D SUB CONNECTOR PIN ASSIGNMENTS 14 POWER MANAGEMENT 15 SPECIFICATIONS 16 TROUBLE SHOOTING GUIDE 17 1 This...

Страница 4: ...your outlet consult an electrician for replacement of the bsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where th...

Страница 5: ...ture The apparatus shall not be exposed to dripping or splashing and no objects filled with liquids such as vases shall be placed on the apparatus This symbol is intended to alert the user to the pres...

Страница 6: ...nit to rain or moisture This unit is designed to be used in the office or home Do not subject the unit to vibrations dust of corrosive gases KEEP IN A WELL VENTILATED PLACE Ventilation holes are provi...

Страница 7: ...y turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation...

Страница 8: ...Rear Connection 1 DC 12V 2 HDMI IN 3 DVI IN 4 VGA IN 5 PC STEREO IN VGA and DVI In 6 UPGRADE 6 1 2 3 4 5 6...

Страница 9: ...The button converts the aspect ratio as 16 9 or 4 3 The button is auto adjustment function in the VGA input 5 6 VOL VOL Adjusts the volume and menu settings The VOL button is the Sound off function 7...

Страница 10: ...ttons to select a sub menu item 6 Press the and buttons to toggle the OSD values 7 Press the Menu button to exit the selected menu and to return to the menu bar or to confirm a selection 8 Press the M...

Страница 11: ...al Cool and User Red Green and Blue Zoom Sets the aspect ration for the monitor 16 9 and 4 3 Information Bar Displays two bars on either side of the image when the monitor displays an image transmitte...

Страница 12: ...stment of the screen geometry Phase Adjusts the number of horizontal picture elements 0 100 Clock Adjusts the vertical noise of screen image 0 100 Display Position Moves the horizontal and vertical po...

Страница 13: ...3 Sound Menu Option Function Value Volume Controls the built in speaker volume 0 100 Mute Enables disables audio On or Off 11...

Страница 14: ...isables the Key Lock function On or Off Image Rotation Activates the Image Rotation function This function slightly moves the displayed image to prevent image persistence On or Off Reset Restores defa...

Страница 15: ...Wall mounting Optional Using the both sides pre cut holes to rack mounting 13 Rack mounting holes...

Страница 16: ...ABLE DETECT 3 BLUE VIDEO 11 GROUND 4 GROUND 12 SDA for DDC 5 GROUND 13 H SYNC or H V SYNC 6 RED GROUND 14 V SYNC 7 GREEN GROUND 15 SCL for DDC 8 BLUE GROUND D SUB Accessories 1 Power cord 2 Power adap...

Страница 17: ...ed On 42W Turned Off 0 5W LED Indicator The power management feature of the monitor is comprised of three stages Turned on Blue and turned off LED off Mode LED Monitor Operation Turned On Blue Normal...

Страница 18: ...1 64kHz Vertical 56 75Hz Input Signal Digital Visual Interface DVI 1 0 HDCP 1 2 VGA RGB PC HDMI Visual Interface HDMI 1 3 PC Stereo in Upgrade Active Display Area H x V 409 8mm x 230 4mm Packing Dimen...

Страница 19: ...onment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household user...

Страница 20: ...MEMO...

Страница 21: ...MEMO...

Страница 22: ...MEMO...

Страница 23: ......

Страница 24: ...P N L39ME0335 Rev 1...

Отзывы: