Viessmann Vitotrol 100 UTDB-RF2 Скачать руководство пользователя страница 3

3

If you smell flue gas

Danger

Flue gas can lead to life threat-
ening poisoning.
■ Shut down the heating system.
■ Ventilate the installation site.
■ Close all doors in the living

space.

Flue systems and combustion air

Ensure that flue systems are clear and
cannot be sealed, for instance due to
accumulation of condensate or other
causes. Ensure a sufficient supply of
combustion air.
Instruct system users that subsequent
modifications to the building characteris-
tics are not permissible (e.g. cable/pipe-
work routing, cladding or partitions).

Danger

Leaking or blocked flue systems,
or an insufficient supply of com-
bustion air can cause life threat-
ening poisoning from carbon
monoxide in the flue gas.
Ensure the flue system is in
proper working order. Apertures
for supplying combustion air
must be non-closable.

Extractors

Operating appliances that extract air to
the outside (cooker hoods, extractors, air
conditioning units, etc.) can create neg-
ative pressure. If the boiler is operated at
the same time, this can lead to reverse
flow of the flue gas.

Danger

The simultaneous operation of
the boiler and appliances that
extract air to the outside can
result in life threatening poison-
ing due to reverse flow of the flue
gas.
Fit an interlock circuit or take suit-
able steps to ensure a sufficient
supply of combustion air.

Working on the system

■ Where gas is used as the fuel, close

the main gas shut-off valve and safe-
guard it against unintentional reopen-
ing.

■ Isolate the system from the power sup-

ply (e.g. by removing the separate fuse
or by means of a mains isolator) and
check that it is no longer 'live'.

■ Safeguard the system against recon-

nection.

Danger

Hot surfaces can cause burns.
■ Before maintenance or service

work, switch OFF the appli-
ance and let it cool down.

■ Never touch hot surfaces on

the boiler, burner, flue system
or pipework.

!

Please note

Electronic assemblies can be
damaged by electrostatic dis-
charge.
Before beginning work, touch
earthed objects, such as heating
or water pipes, to discharge static
loads.

Safety instructions

Safety instructions

 (cont.)

5461 060 GB

 

Содержание Vitotrol 100 UTDB-RF2

Страница 1: ...ions for contractors VIESMANN Vitotrol 100 Type UTDB RF2 Room temperature controller with digital time switch and wireless receiver for Vitodens 050 W For applicability see the last page VITOTROL 100 5461 060 GB 1 2014 Please keep safe ...

Страница 2: ...working on this system Statutory regulations regarding the prevention of accidents Statutory regulations regarding envi ronmental protection The Code of Practice of relevant trade associations All current safety regulations as defined by DIN EN DVGW TRGI TRF VDE and all locally applicable standards a ÖNORM EN ÖVGW TR Gas ÖVGW TRF and ÖVE c SEV SUVA SVGW SVTI SWKI VKF and EKAS guideline 1942 LPG pa...

Страница 3: ... neg ative pressure If the boiler is operated at the same time this can lead to reverse flow of the flue gas Danger The simultaneous operation of the boiler and appliances that extract air to the outside can result in life threatening poison ing due to reverse flow of the flue gas Fit an interlock circuit or take suit able steps to ensure a sufficient supply of combustion air Working on the system...

Страница 4: ...pare and wearing parts Please note Spare and wearing parts that have not been tested together with the system can compromise its function Installing non author ised components and making non approved modifications or conversions can compromise safety and may invalidate the warranty For replacements use only orig inal spare parts supplied or approved by Viessmann Safety instructions Safety instruct...

Страница 5: ...ce Installing and connecting the wireless receiver 7 Installing the Vitotrol 100 9 Service instructions Commissioning Commissioning the Vitotrol 100 12 Commissioning the wireless receiver 12 Service settings Changing the address code 14 Specification 15 Declaration of Conformity 16 Index Index 5461 060 GB ...

Страница 6: ...oor level Not near windows or doors Not on shelves or in recesses Away from heat sources such as radiators insolation fireplace television Wireless reception good communica tion with the wireless receiver must be possible see page 13 Never install further control devices in this main living room If the radiators are equipped with thermostatic valves these must always be fully opened Wireless recei...

Страница 7: ...ireless receiver Please note Electronic assemblies can be damaged by electrostatic dis charge Prior to commencing any work touch earthed objects such as heating or water pipes to dis charge static loads Installation sequence Installing and connecting the wireless receiver 5461 060 GB Installation ...

Страница 8: ...ol unit enclosure and push the plug into X5 The plug must click home Note Route the lead in such a way that it does not become trapped as the control unit enclosure is closed Installation sequence Installing and connecting the wireless receiver cont 5461 060 GB ...

Страница 9: ...4 5 1 Fitting the wall mounting base Always check reception prior to fitting to the wall see page 13 Power is supplied by batteries see chapter Specification Installation sequence Installing the Vitotrol 100 5461 060 GB Installation ...

Страница 10: ...10 1 2 3 Installation sequence Installing the Vitotrol 100 cont 5461 060 GB ...

Страница 11: ...11 Assembling the Vitotrol 100 1 2 3 4 5 Installation sequence Installing the Vitotrol 100 cont 5461 060 GB Installation ...

Страница 12: ...ction r Heat demand for central heat ing Heat demand for DHW heating Several Vitotrol 100 and the wireless receiver can be installed in one building Each set is matched in the factory Each Vitotrol 100 can only communicate with its allocated wireless receiver Note If LED r flashes the wireless receiver has not recognised the signal from the Vitotrol 100 In this case change the address code see pag...

Страница 13: ...totrol 100 Testing switching outputs 1 Press B on the wireless receiver see diagram on page 12 repeatedly until the required condition is reached see following table 2 Terminate the function Press B This function ends automatically if the switching output is switched off by the Vitotrol 100 settings Function LED r LED Central heating and DHW heating OFF OFF OFF Central heating OFF DHW heating enab...

Страница 14: ...ol 100 Open the flap of the Vitotrol 100 3 Press twice 4 Select Settings with 5 Confirm with OK 6 Select Service with 7 Press OK three times to confirm 8 Select Address code with 9 Confirm with OK After approx 30 s the display shows Transmitting The transmission takes approx 30 s LED flashes briefly during trans mission The LED extinguish when the address code has been recognised If not repeat the...

Страница 15: ...o EN 60529 Safety category II to EN 60730 1 Radio frequency 868 MHz Wireless receiver Power supply From the control unit Ambient temperature 0 to 40 C IP rating As for the boiler Transmission from the Vitotrol 100 With every heat demand and heat draw off With every demand for DHW heating Cyclically every 20 min Specification Specification 5461 060 GB Service ...

Страница 16: ...4 1 2002 In accordance with the following Directives this product is designated with _ 2004 108 EC 1999 5 EC Allendorf 01 January 2014 Viessmann Werke GmbH Co KG Authorised signatory Manfred Sommer Applicability Serial No 7537991 Viessmann Limited Hortonwood 30 Telford Shropshire TF1 7YP GB Telephone 44 1952 675000 Fax 44 1952 675040 E mail info uk viessmann com Viessmann Werke GmbH Co KG D 35107 ...

Отзывы: