![Viessmann VITOSOL 200-T SP2A Скачать руководство пользователя страница 3](http://html.mh-extra.com/html/viessmann/vitosol-200-t-sp2a/vitosol-200-t-sp2a_technical-data-manual_1018138003.webp)
Vitosol 200-T, SP2A Technical Data
3
5782 590 - 02
Product Information
3
Specification
Vitosol 200-T
1.26 m
2
1.51 m
2
3.03 m
2
Number of tubes
10
12
24
Gross area
ft
2
(m
2
)
21.3 (1.98)
25.4 (2.36)
49.7 (4.62)
Absorber area
ft
2
(m
2
)
13.6 (1.26)
16.3 (1.51)
32.6 (3.03)
Aperture area
ft
2
(m
2
)
14.3 (1.33)
17.2 (1.60)
34.3 (3.19)
Installation position
(see figure below)
A
,
B
,
C
,
D
,
E
,
F
Spacing between collectors
in. (mm)
--
3.5 (88.5)
3.5 (88.5)
Dimensions
Width ‘a’
Height ‘b’
Depth ‘c’
in. (mm)
in. (mm)
in. (mm)
34.8 (885)
88.2 (2241)
5.9 (150)
41.5 (1053)
88.2 (2241)
5.9 (150)
81.1 (2061)
88.2 (2241)
5.9 (150)
The following values apply to the absorber area:
(as tested by TUV testing laboratories in Europe)
– Optical efficiency
– Heat loss factor k1
– Heat loss factor k2
%
k1 W/(m
2
· K)
k1 W/(m
2
· K
2
)
78.5
1.42
0.005
78.5
1.42
0.005
78.5
1.42
0.005
Thermal capacity
kJ/(m
2
· K)
8.4
8.4
8.4
Weight
lb(kg)
73 (33)
86 (39)
174 (79)
Liquid content
(heat transfer medium)
USG (L)
0.198 (0.75)
0.23 (0.87)
0.41 (1.55)
Permissible operating pressure
psig (bar)
87 (6)
87 (6)
87 (6)
Maximum stagnation temperature
°F (°C)
557 (292)
557 (292)
557 (292)
Connection
Ø in. (Ø mm)
¾ (22)
¾ (22)
¾ (22)
Tested quality
The collectors meet the requirements of the “Blue Angel”
eco-label to RAL UZ 73.
Tested in accordance with Solar KEYMARK, EN 12975
and SRCC 0G-100
CR Collector return