19
Collector installation
(cont.)
Interconnecting pipes must be free
from damage and contamination.
Lubricate all plug-in joints (OĆring
seals) on the collectors
only
with the
special grease supplied with the
connection set.
On the first and last collector, the
side to which the type plate is
affixed,
must
be on the
outside
.
Route the piping on only one
collector
opposite
the type plate
side.
1.
Hook the collector into its
mounting plates and lay down
onto the mounting rails.
2.
Secure the collector with four
clamping bolts onto the mounting
rails; only tighten the two
outer
clamping bolts.
Turn the grooved bolt 90Ă
º
.
3.
Insert the connecting pipe until it
bottoms out inside the collector
connections.
4.
Position the second collector as
described under itemĂ1.
5.
Carefully push the second
collector against the first and
insert the connecting pipes until
they bottom out.
Distance from the lower edge of
the installed collector
16Ămm.
6.
Install additional collectors.
7.
Tighten
all
clamping bolts.
8.
Remove the label.
9.
Press the cover caps (part of the
connection set) into the mounting
rails.
5862Ă511 GB