Fault messages during operation
These fault messages are indicated by codes "FE" or "In".
The boiler returns to operation when the relevant fault has been removed.
Note
After a fault has been removed, press the reset button.
Operating instructions
Display
indication
Explanation/Cause/Effect
Remedy
FE 238
The supply draws no pellets.
The boiler will not start.
Change to another wand if there
are no pellets near the supply
wand (see operating instruc-
tions).
Check the routing and layout of
the supply hose or the suction
wand.
FE 239
Automatic pellet supply chan-
geover faulty.
Check the automatic change-
over.
FE 281
Flue gas temperature sensor
faulty.
The flue gas temperature can-
not be displayed.
No effect on the operation.
Check the flue gas temperature
sensor (see page 26).
FE 381
Hopper empty.
Start the pellet supply or wait for/
change the enable time.
The fully automatic pellet sup-
ply is switched off.
The pellet supply has stopped
as it is currently outside the se-
lected enable time.
FE 382
The level switch inside the hop-
per does not switch.
The boiler will not start.
The pellet supply flap does not
close.
Open the pellet hopper (see
page 16) and clean the flap; it
must lie flush all around the sup-
ply. The indicator on the level
switch must be brightly lit when
the flap is closed.
The level switch inside the hop-
per is faulty.
Replace the level switch.
Fault messages
22
Troubleshooting
5692
618
GB
Содержание Vitolig 300
Страница 27: ...Standard control Connection and wiring diagrams 27 Connection and wiring diagrams 5692 618 GB ...
Страница 37: ...Parts list cont 37 Parts lists 5692 618 GB ...
Страница 38: ...Parts list cont 38 Parts lists 5692 618 GB ...
Страница 39: ...Parts list cont 39 Parts lists 5692 618 GB ...
Страница 40: ...Parts list cont 40 Parts lists 5692 618 GB ...
Страница 41: ...Parts list cont 41 Parts lists 5692 618 GB ...
Страница 42: ...Parts list cont 42 Parts lists 5692 618 GB ...
Страница 43: ...Parts list cont 43 Parts lists 5692 618 GB ...