14
Yes
Burner in opera-
tion.
The green LED on
the ignition trans-
former is perma-
nently on (a flame
is recognised).
For further details regarding faults, see
page 63.
Adjusting the standard burner settings
Standard burner settings
Note
Check that the service instructions are valid for the relevant burner (see applicability
on the last page and the serial no. on the boiler type plate).
A
A
Flue gas test port
Rated output
kW
12.9/19.3
16.1/23.5
Burner stage
Stage 1
Stage 2
Stage 1
Stage 2
Rated output
kW
12.9
19.3
16.1
23.5
Oil burner nozzle
Type
80°H LE V
80°H LE V
Make: Danfoss
Gph
0.40
0.50
Commissioning, inspection, maintenance
Further details regarding the individual steps
(cont.)
5692 799 GB