![Viessmann VITOGAS Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/viessmann/vitogas/vitogas_technical-manual_1017321021.webp)
Peak output (during 10 minutes)
Relative to the performance factor N
L
.
DHW heating from 10 to 45 °C.
Capacity
l
160
200
300
500
750
1000
Peak output (l/10 min) at a heating water flow temper-
ature of
90 °C
210
262
407
618
898
962
80 °C
207
252
399
583
814
939
70 °C
199
246
385
540
704
898
Max. draw-off rate (over 10 minutes)
Relative to the performance factor N
L
.
With booster heating.
DHW heating from 10 to 45 °C.
Capacity
l
160
200
300
500
750
1000
Max. draw-off rate (l/min) at a heating water flow tem-
perature of
90 °C
21
26
41
62
90
96
80 °C
21
25
40
58
81
94
70 °C
20
25
39
54
70
90
Available water volume
Cylinder content heated to 60 °C.
Without booster heating.
Capacity
l
160
200
300
500
750
1000
Draw-off rate
l/min
10
10
15
15
20
20
Available water volume
water at t = 60 °C (continuous)
l
120
145
240
420
615
835
Heat-up time
The heat-up times will be achieved, if the max. continuous output of
the DHW cylinder is made available at the respective heating water
flow temperature and when heating DHW from 10 to 60 °C.
Capacity
l
160
200
300
500
750
1000
Heat-up time (min.) at a heating water flow tempera-
ture of
90 °C
19
19
23
28
24
36
80 °C
24
24
31
36
33
46
70 °C
34
37
45
50
47
71
DHW cylinder
(cont.)
VITOGAS
VIESMANN
21
5822 428 GB
3