Operating instructions

for the system user

VIESMANN

DHW heat pump
Type T0E 060-A with immersion heater EHE

VITOCAL 060-A

5593131 GB

5/2018

Please keep safe.

Содержание T0E 060-A

Страница 1: ...Operating instructions for the system user VIESMANN DHW heat pump Type T0E 060 A with immersion heater EHE VITOCAL 060 A 5593131 GB 5 2018 Please keep safe ...

Страница 2: ...ot be car ried out by unsupervised children Appliance connection The appliance may only be connected and commis sioned by authorised contractors Observe the specified electrical connection require ments Modifications to the existing installation may only be carried out by authorised contractors Danger Incorrectly executed work on the system can lead to life threatening accidents Work on electrical...

Страница 3: ...permissible ambient tempera tures as detailed in the operating instructions Appliance for indoor installation Avoid air contamination through halogenated hydrocarbons e g as in paints solvents and cleaning agents Avoid continuously high humidity levels e g through continuous drying of washing Auxiliary components spare and wearing parts Please note Components that were not tested with the sys tem ...

Страница 4: ...ene 16 4 Power from a photovoltaic system Utilisation of power generated on site 17 5 Further settings Setting the time and day 18 Premium economy tariff 18 Enable premium economy tariff 18 Minimum stop time function 18 Childproofing 18 Restoring factory settings reset 19 6 Checks Checking information 20 Checking messages 20 7 Switching on and off Switching off the DHW heat pump 21 With frost prot...

Страница 5: ...5 10 Keyword index 25 Index Index cont 5593131 ...

Страница 6: ...ating instruc tions The appliance may only be used for heating DHW The range of functions can be extended with additional components and accessories Intended use presupposes that a fixed installation in conjunction with permissible system specific compo nents has been carried out Commercial or industrial use for purposes other than domestic hot water heating shall be deemed inappro priate Any usag...

Страница 7: ...d down during DHW heating is dis charged directly to the outside via a further duct Commissioning The commissioning and matching up of the heat pump control unit to local conditions and to the structural characteristics of the building plus the instruction of the user in operating the system must be carried out by your heating contractor Permissible air intake temperatures The DHW heat pump switch...

Страница 8: ...f the heat pump control unit please contact your contractor Tips for greater comfort Higher DHW demand Heat up the DHW cylinder more often For this con sult your contractor see page 15 Use the immersion heater for automatic DHW cylin der reheating e g at low ambient or outside temper atures or if the DHW heat pump develops a fault Set the AUTO operating program BOOST operating program see page 12 ...

Страница 9: ...erating program is selected 21 Display and set times 18 PROG PROGRAM operating program is selected 15 Night NIGHT operating program is selected 10 Display information 20 Heat pump is enabled flashes Heat pump starts once the minimum stop time has expired 18 Immersion heater is enabled Premium economy tariff is enabled 18 flashes Economy tariff is active Star rotates Increased DHW hygiene function ...

Страница 10: ...um econ omy tariff please contact your heating contrac tor 1 Installation with premium economy tariff For further information on the premium economy tariff please contact your heating contractor I6 Setting for the PROGRAM operating program Off Standard On NIGHT mode Optimum heating of DHW cyl inder between 23 00 and 5 00 Operating program See page ECO 11 SMART 12 AUTO 12 BOOST 12 OUT holiday progr...

Страница 11: ...10 20 30 40 50 60 70 Air intake temperature in C DHW temperature in C A 6 62 Fig 3 A DHW temperature achievable with the heat pump 62 C ECO operating program DHW is only heated by the heat pump and only up to the max DHW temperature of the heat pump Outside temperature from 5 C to 35 C 0 DHW temperature in C Fig 4 A Heat pump B Immersion heater C DHW temperature achievable with the heat pump Outsi...

Страница 12: ...ture achievable with the heat pump Outside temperature below 2 5 C 0 DHW temperature in C Fig 7 A Heat pump B Immersion heater C DHW temperature achievable with the heat pump D Standard DHW temperature AUTO operating program DHW is heated by the heat pump as a priority The immersion heater is started automatically depend ing on the air intake temperature and the set DHW temperature Outside tempera...

Страница 13: ...g 11 A Heat pump B Immersion heater C DHW temperature achievable with the heat pump D Standard DHW temperature BOOST OUT operating program holiday program Standby mode with frost protection for the DHW heat pump Only minimal heating of the DHW 3 C The duration in days can be adjusted Note If the DHW temperature falls below 5 C the frost pro tection function is enabled Outside temperature from 5 C ...

Страница 14: ...mmersion heater is only switched on for frost pro tection Outside temperature from 5 C to 35 C 0 DHW temperature in C 10 Fig 16 A Heat pump B Immersion heater C DHW temperature achievable with the heat pump D Standard DHW temperature PROG Outside temperature below 5 C or above 35 C 0 DHW temperature in C 10 Fig 17 A Heat pump B Immersion heater C DHW temperature achievable with the heat pump D Sta...

Страница 15: ... C or above 35 C 0 DHW temperature in C 10 Fig 21 A Heat pump B Immersion heater C DHW temperature achievable with the heat pump D Standard DHW temperature PROG Setting a time program In the time program you define when DHW is heated in the PROGRAM operating program Settings Explanation WEEK You can set a time program that is the same every day of the week You can set separate time programs for ea...

Страница 16: ... 2 people to XL 4 people to accommodate a higher DHW demand or provide greater convenience This change may only be made by your contractor Increased DHW hygiene This function allows you to improve the microbiological quality of the water in the DHW cylinder To ensure increased DHW hygiene the drinking water in your DHW cylinder can be heated to 60 C at regu lar intervals Your contractor can set th...

Страница 17: ...17 You can use the power generated by your photovoltaic system for DHW heating For this consult your contractor Power from a photovoltaic system Utilisation of power generated on site 5593131 ...

Страница 18: ... switch on DHW heating at any time regardless of the electricity tariff Note The PROGRAM operating program and the time setting are no longer available Enable premium economy tariff The premium economy tariff must have been connec ted and enabled by your contractor Select the ECO or AUTO operating program Premium economy tariff is used When electricity is cheaper economy tariff the symbol flashes ...

Страница 19: ...he PROGRAM operating program 1 Press and hold and OK simultaneously for 3 seconds RST is displayed 2 Confirm with OK dONE appears The factory settings have been restored Note Time and date need to be set again 3 Use to exit RST Further settings Restoring factory settings reset 5593131 ...

Страница 20: ...ays 22 HP 78 Time percentage of DHW heating provided by the heat pump in the last 30 days 78 Displaying information 1 Use to select information 2 Use OK to switch between displays Note To reset the values press and OK simultane ously 3 Return to the last operating program with Checking messages Messages are shown if your DHW heat pump experi ences particular events or operating conditions If fault...

Страница 21: ...to reset the date and time see page 18 Switching on the DHW heat pump After being taken out of use or a power failure lasting longer than 24 hours 1 Check that the power plug is plugged in Switch on the power supply e g at a separate fuse or a mains isolator After a few seconds the appliance starts in the ECO operating program flashes 2 Note If the time and day are displayed alternately see page 1...

Страница 22: ...o select the required operating program Your DHW heat pump has only just shut down and can not restart immediately No action required The minimum stop time is active Wait approx 5 mi nutes A message ER 0 to ER 10 is displayed Notify your contractor Tell your contractor which fault message is being displayed No input is possible at the programming unit Cause Remedy Childproofing is on Press and sim...

Страница 23: ... this is refilled in good time For this observe the manufacturer s instructions We recommend an annual function check of the pro tective magnesium anode by your contractor The function of the protective magnesium anode can be checked without interrupting operation The con tractor will check the earth current with an anode tester Safety valve DHW cylinder The function of the safety valve must be ch...

Страница 24: ...y disposal sys tem Altstoff Recycling Austria AG licence num ber 5766 Final decommissioning and disposal of the heating system Viessmann products can be recycled Components and fluids from your heating systems are not part of ordinary domestic waste Please speak to your contractor about the correct dis posal of your old system DE Operating fluids e g heat transfer medium can be disposed of at muni...

Страница 25: ...formation checking 20 Inspection 23 L Lower cylinder temperature sensor 16 M Maintenance 23 Cleaning 23 DHW cylinder 23 Maintenance contract 23 Minimum stop time function 18 P Permissible air intake temperatures 7 Photovoltaic system energy saving 8 Power failure 7 Power from photovoltaic system 17 Power plug 21 Power supply 21 Premium economy tariff 18 R Reset 19 S Setting DHW temperature 10 Shut...

Страница 26: ...26 5593131 ...

Страница 27: ...27 5593131 ...

Страница 28: ...n find local contractors on the internet at www viessmann de Viessmann Limited Hortonwood 30 Telford Shropshire TF1 7YP GB Telephone 44 1952 675000 Fax 44 1952 675040 E mail info uk viessmann com Viessmann Werke GmbH Co KG D 35107 Allendorf Telephone 49 6452 70 0 Fax 49 6452 70 2780 www viessmann com 5593131 Subject to technical modifications ...