8
Angle of inclina-
tion
α
Collector row clearance z in mm
Type SV
Type SH
Flensburg
30°
7630
5715
45°
9600
4260
60°
10,890
4830
Kassel
30°
6385
2845
45°
7840
3480
60°
8720
3870
Angle of inclina-
tion
α
Collector row clearance z in mm
Type SV
Type SH
Munich
30°
5595
2485
45°
6710
2980
60°
7350
3260
Installation information
■
Align the collector array to face due south, or as
close to due south as possible.
■
Observe the maximum load and distance from the
edge of the roof for the on-site substructure to
DIN 1055.
■
Installation on concrete slabs
A
Remove any gravel or similar from the installation
area, cover the surface with protective building mats
and position support slabs on top of these mats.
■
Installation on steel beams
B
Install the on-site substructure at right angles to and
horizontally level with the collector orientation.
■
The Viessmann "SOLSTAT" calculation program is
available at
www.viessmann.com
to assist with bal-
last calculations.
Calculating collector row clearance z
(cont.)
5727 904 GB