62
en-US/C
A
6.3
Overview of options and their para-
meters
In the following, the additional options and para-
meters are listed.
The options and parameters displayed depend on the
system as well as on the options and functions which
have been selected. Some of the options and para-
meters will only be displayed, if they are available with
the individual adjustments.
Channels
Channel
Sub channel 1
Sub channel 2 Factory setting
Change to
Description
Page
COOL >
Cooling functions
OSYC*
OFF
System cooling
51
DTCO
20 K [40 °Ra]
Switch-on difference system cooling
51
DTCF
15 K [30 °Ra]
Switch-off difference system cooling
51
OSTC
OFF
Tank cooling
52
OHDP*
OFF
Heat dump
52
OTCL
110 °C [230 °F]
Overtemperature collector
52
OTPUM
OFF
Pump or valve logic
52
ODTFT >
∆
T function option
54
DT4O
6.0 K [12.0 °Ra]
∆
T function switch-on difference
54
DT4F
4.0 K [8.0 °Ra]
∆
T function switch-off difference
54
RIS4
2 K [4 °Ra]
∆
T function rise
55
TH1O
65.0 °C [150.0 °F]
Thermostat function 1 switch-on temperature
55
TH1F
60.0 °C [140.0 °F]
Thermostat function 1 switch-off temperature
55
TH2O
45.0 °C [120.0 °F]
Thermostat function 2 switch-on temperature
55
TH2F
50.0 °C [125.0 °F]
Thermostat function 2 switch-off temperature
55
DTREL
4
∆
T function relay
55
OTH >
Thermostat function option
THNHE
40 °C [110 °F]
Thermostatic backup heating switch-on temperature
55
THNHA
45 °C [120 °F]
Thermostatic backup heating switch-off temperature
55
S TH
3 / 5
Thermostatic backup heating sensor
56
RTH
Thermostatic backup heating relay
t1O
06:00
Thermostatic backup heating switch-on time 1
55
t1F
22:00
Thermostatic backup heating switch-off time 1
55
t2O
00:00
Thermostatic backup heating switch-on time 2
56
t2F
00:00
Thermostatic backup heating switch-off time 2
56
t3O
00:00
Thermostatic backup heating switch-on time 3
56
t3F
00:00
Thermostatic backup heating switch-off time 3
56
PUMP >
Speed
PUMP1
OnOF
Speed variant pump 1
45