29
Troubleshooting
Diagnostics
(cont.)
Fault
code
System
characteristics
Cause
Remedy
32
Burner control unit in
fault state
Error in feedback
from auxiliary
start−up valve, output
relay does not
activate
Replace burner
control unit
35
Error in feedback
from ignition, output
relay does not
activate
36
Fan speed during
start−up or operation
stays outside its set
range longer than
5s, speed for ignition
setting or start
output during
operation is not
achieved
Fan faulty, cables
faulty or broken
Check cables,
replace fan
37
Fan does not reach
set speed
Fan faulty, cables
faulty or short
circuited, fan blocked
by debris
Check cables,
replace fan, remove
debris
42
Burner control unit
remains in start−up
position; no start−up
in spite of heat
demand
Safety chain broken
Check jumper(B
2) of
safety chain
4E
Burner control unit in
fault state
Internal error
Replace burner
control unit
Scrolling
change−
over
display:
123
457
Constant start
attempt
CoresL
1 and N at
control unit mains
supply interchanged
Check mains supply
and swap cores
5692541 GB
Содержание MatriX radiant burner
Страница 35: ...35 Component summary Component summary 5692 541 GB B P N E O H K L M E F G A B C D...
Страница 39: ...39 Parts list Parts list cont 5692 541 GB 006 007 003 002 036 036 035 036 009 001 5o 008 009...
Страница 41: ...41 Appendix 5692 541 GB...
Страница 43: ...43 Appendix Maint service Maint service Maint service Maint service 5692 541 GB...
Страница 45: ...45 Appendix Maint service Maint service Maint service Maint service 5692 541 GB...
Страница 47: ...47 Appendix Maint service Maint service Maint service Maint service 5692 541 GB...