46
Mechanical
ventilation
system with Vitovent
System:
Heating
contractor:
Contact:
Date:
Air flow rates for 0.5 x air change
rate
Appliance
settings
=......................m³/h
..................m³/h
Total flow rate
Supply
air
Extract air
..................m³/h
..................W
Power consumption
Supply
and
extract air vents
Supply
air
Living
room
Living
room
Dining
room
Bedroom Study Child's
room 1
Child's
room 2
Intended flow rate [m³/h]
Supply
air/
Extr.
air
valve
Preset aperture
width
First test (average)
Air velocity [m/s]
Air flow rate [m³/h]
Readjusted aperture
width
Second
test
(average)
Air velocity [m/s]
Air flow rate [m³/h]
Total supply
air
Extract air
Kitchen
Bathroom
Guest WC
Utility room
Total extract air
Sample
person
160
163
152
46
25
25 25
30
30
25
160
60
45
20
25
160
Wall installation
Wall installation Wall installation
Ceiling
installat.
Ceiling
installat.
Ceiling
installat.
5.5
5.5
5.5
6
6 5
3.5
3.5 3.5
3.0
4.0
2.5
22
22
22 24
36
20
146
+1
+1
+1 +2
-1
+1
3.3
3.3 3.3
3.2
3.8
2.6
25
25 25
36
30
22
163
Kitchen Extr.
air
valve
Extr.
air
valve
Extr.
air
valve
Extr.
air
valve
+12
+9
+10
-8
6.3
5.2
5.0
6.0
50
38
15
20
137
-
+4
+3
+7
4.0
4.4
4.2
3.2
70
42
20
20
152
Fig. 40
Commissioning/service reports
Sample commissioning report
5793 605 GB
Appendix