113
Pump/component
Parameter
Setting
Circulation pump for
DHW reheating
"External heat source"
Ó
"Enable external heat
source 7B00"
"1"
"External heat source"
Ó
"Enable external heat
source for DHW heating
7B0D"
"1"
Solar thermal system
"Solar"
Ó
"Type solar control unit
7A00"
■
"1"
(with Vitosolic 100)
■
"2"
(with Vitosolic 200)
Remote control
(e.g. Vitotrol 200A)
"Heating circuit 1"
Ó
"Remote control 2003"
or
"Heating circuit 2"
Ó
"Remote control 3003"
or
"Heating circuit 3"
Ó
"Remote control 4003"
"1"
Note
Set code at the Vitotrol 200A
to assign heating circuits:
H1 for heating circuit A1
H2 for heating circuit M2
H3 for heating circuit M3
(see Vitotrol 200 A installa-
tion instructions)
Vitocom 100
"System definition"
Ó
"Vitocom 100 7017"
"1"
External extension H1
"System definition"
Ó
"External extension
7010"
"1"
Note
For parameters for external
functions, see separate
table.
Commissioning, inspection, maintenance
Further details regarding the individual steps
(cont.)
5600 161 GB
Service