Fig. 15
■
If the device is
not
integrated into a CAN bus sys-
tem:
Switch
A
must
not
be set to "ON".
■
If the device is integrated into a CAN bus system and
is located at the beginning or end of this system (not
in the middle) of the CAN bus system (connected to
only one plug
lA
): Set switch
A
to "ON".
C
C
A
91 91
B
B
ON
Fig. 16
A
Heat generator / HMU heat management unit
B
CAN bus cable
C
CAN bus other subscribers
■
If the device is integrated into a CAN bus system and
is
not
located at the beginning or end of the CAN
bus system (both plugs
lA
connected): Do
not
set
switch
A
to "ON".
A
C
C
B
B
91 91
ON
Fig. 17
Power supply for accessories at plug
lH
/
aBH
(230 V ~)
When positioned in wet rooms, accessories outside
the wet area must not be connected to the power sup-
ply at the HMU heat management unit. If the boiler is
not sited in a wet room, the power supply for accesso-
ries can be connected directly to the HMU heat man-
agement unit. This connection is switched directly with
the ON/OFF switch of the appliance.
If the total system current exceeds 6 A, connect one or
more extensions directly to the mains supply via an
ON/OFF switch (see next chapter).
Installation sequence
Electrical connections
(cont.)
6151778
Installation