29
Type AWT/AWT-AC
Line
Connection to the
indoor unit
Torque in Nm
221.A07
Liquid line
7
10 mm
⅝
UNF
33 to 42
Hot gas line
7
16 mm
⅞
UNF
63 to 77
221.A10
Liquid line
7
10 mm
⅝
UNF
33 to 42
Hot gas line
7
16 mm
⅞
UNF
63 to 77
221.A13
Liquid line
7
10 mm
⅝
UNF
33 to 42
Hot gas line
7
16 mm
⅞
UNF
63 to 77
221.B10
Liquid line
7
10 mm
⅝
UNF
33 to 42
Hot gas line
7
16 mm
⅞
UNF
63 to 77
221.B13
Liquid line
7
10 mm
⅝
UNF
33 to 42
Hot gas line
7
16 mm
⅞
UNF
63 to 77
221.B16
Liquid line
7
10 mm
⅝
UNF
33 to 42
Hot gas line
7
16 mm
⅞
UNF
63 to 77
Connecting the secondary circuit
Opening the casing door
1.
Fig. 21
2x
3.
2x
2.
A
B
Fig. 22
A
Straight pipe sections supplied
B
Pipe bends from secondary circuit connection set
(accessories): See separate installation instruc-
tions.
Symbol
Meaning
Connection
Heating water return
Cu 28 x 1 mm
Heating water flow
Cu 28 x 1 mm
Installation sequence
Connecting the refrigerant lines
(cont.)
5776 028 GB
Installation
Содержание AWT 221.A04
Страница 77: ...77 Maintenance Checking the fuses cont 5776 028 GB Maintenance...
Страница 87: ...87 Indoor unit parts lists Indoor unit hydraulics cont 5776 028 GB Components...
Страница 90: ...90 Indoor unit parts lists Indoor unit cylinder cont 5776 028 GB Components...
Страница 137: ...137 Wind direction 11 Wind loads 11 Keyword index Keyword index cont 5776 028 GB...
Страница 138: ...138 5776 028 GB...
Страница 139: ...139 5776 028 GB...