background image

L

M

H

0

10

20

30

40

150

200

250

300

Statica

uti

le

[KP

a]

Static

p

re

ssu

re

[KP

a

]

Portata

aria

[mc/h]

Air

flow

rate

[mc/h

]

Statica

utile

alle

velocità

L,

M,

H

del

ventilatore

DHS/DHSC

220

Static

pressure

at

fan

speed

L,M,H

DHS/DHSC

L

M

H

0

10

20

30

40

200

250

300

350

400

450

500

Statica

uti

le

[KP

a]

Static

pr

es

su

re

[KPa

]

Portata

aria

[mc/h]

Air

flow

rate

[mc/h

]

Statica

utile

alle

velocità

L.

M,

H

del

ventilatore

DHS/DHSC

360

Static

pressure

at

fan

speed

L,

M,

H

DHS/DHSC

360

fig. 4

2.2.2 PERDITE DI CARICO CIRCUITO IDRAULICO (fig. 4)

2.2.2 HYDRAULIC CIRCUIT PRESSURE DROP (fig. 4)

serie

 

series

 

DH

VIESSMANN    

9

Содержание 7548288

Страница 1: ...DH DEUMIDIFICATORI PER IMPIANTI DI CLIMATIZZAZIONE RADIANTE DEHUMIDIFIERS FOR RADIANT AIR CONDITIONING SYSTEMS...

Страница 2: ...dostato ambiente UM 10 3 1 2 Controcassa solo per DHP220 WB 10 3 1 3 Pannello frontale solo per DHP220 FP 10 RESIDENTIAL VENTILATION CONTENTS INTRODUCTION 3 1 TECHNICAL SPECIFICATIONS 4 1 1 General ch...

Страница 3: ...o a valle del condensatore il deumidificatore impiegando limitate poten ze reimmette aria alle idonee condizioni di umidit specifica ed a temperatura simile a quella di ingresso serie series DH INTROD...

Страница 4: ...Scheda elettronica a display e led luminosi per la gestione ed il controllo delle funzioni DHS220 DHS220 C a soffitto for ceiling mounting DHS360 360 C a soffitto for ceiling mounting DHP220 da parete...

Страница 5: ...portata d aria nominale con le seguenti condizioni aria ambiente 26 C BS UR 65 temperatura acqua ingresso 15 C The performance refers to the nominal air flow rate under the following conditions Ambien...

Страница 6: ...220 DHS220 C DHS360 DHS360 C DHP220 1 3 LAYOUT AND DIMENSIONS Unit is available is available in the following configurations fig 1 2 DHS220 DHS220 C DHS360 DHS360 C DHP220 C I1 D1 D2 A B L1 E1 L2 G1 E...

Страница 7: ...connessioni idrauliche ed elettriche presente sul pannello laterale su quello posteriore e su quello inferiore pre shearing for hydraulic and electrical connections on the side rear and bottom panel f...

Страница 8: ...3 fig 3 0 2 4 6 8 10 12 14 0 50 100 150 200 250 300 350 Perdita di carico KPa Pressure drop KPa Portata l h Water flow rate l h Perdite di carico circuito idraulico DHS DHSC DHP 220 Hydraulic circuit...

Страница 9: ...at fan speed L M H DHS DHSC L M H 0 10 20 30 40 200 250 300 350 400 450 500 Statica utile KPa Static pressure KPa Portata aria mc h Air flow rate mc h Statica utile alle velocit L M H del ventilatore...

Страница 10: ...rte inferiore dello schienale sono presenti dei magneti che ne permettono il fissaggio alla controcassa B fig 7 Dimensioni del pannello 900 x 660 x 20 mm 3 1 ACCESSORIES 3 1 1 ROOM HYGROSTAT UM It all...

Страница 11: ...serie series DH NOTE NOTES VIESSMANN 11...