background image

U S E R     G U I D E

G

H

X

PLUS

HEAD / BODY

HEAD 

A

B

C

D

E

F

LED module

Middle support

Front support

X-Plus Nasal 

applicator

USB-A 

power plug

Nasal applicator

plug

Start button 

and indicator*

1

X-Plus Head 

Module

V3

I

* INDICATOR

Green steady: Device is connected to power source.

Green blinking: Device is in use.

Red blinking: Low power, re-charge power bank.

Power 

adapter

Содержание XPLUS HEAD

Страница 1: ...t Front support X Plus Nasal applicator USB A power plug Nasal applicator plug Start button and indicator 1 X Plus Head Module V3 I INDICATOR Green steady Device is connected to power source Green blinking Device is in use Red blinking Low power re charge power bank Power adapter ...

Страница 2: ...cator 2 N LED module M L Back support X Plus Body Module J USB A power plug I INDICATOR Green steady Device is connected to power source Green blinking Device is in use Red blinking Low power to re charge power bank Power adapter ...

Страница 3: ...nsert nasal applicator E into either the right or the left nostril with the clip on the outside and the lens in the nostril A B C E 3 RECOMMENDED USAGE For cerebellum Use once every two days The X Plus can be used on various parts of the body such as on the head thymus gland and gut Position the LED module C aligned with the middle of the ear Adjust the supports A and B by sliding them along the s...

Страница 4: ...o begin a session The unit switches off automatically after about 20 minutes USING THE X PLUS BODY ON THE THYMUS OR THE GUT 3 4 2 1 RECOMMENDED USAGE Position the LED module on the gut For best fit push or pull the metal band The length of the band can be shortened or lengthened by pushing or pulling the metal band in or out of the holders 4 For thymus Use once daily For gut Use once daily Insert ...

Страница 5: ...light com or chat at www vielight com NOTE 1 To clean the Nasal Applicator wipe gently with 70 alcohol or antiseptic wipes clean gently with soap and water or sanitized with a UV lamp 2 Use a soft dry cloth to clean the other surfaces Do not use abrasive cleaners 3 Do not submerge any of the components on the headset in liquid or cover with other material during use 4 Store in a dry and dust free ...

Страница 6: ...FETY ADVICE LIGHT SOURCE Nasal applicator LED module 6 Caution Do not stare at the lights LED Specifications Light source LED module 810 nm LED 20 mW for application to head Light source LED module 810 nm LED 50 mW for application to body Light source nasal applicator 633 nm LED 6 5 mW General Specifications Treatment duration Automatic shut off at 20 0 1 minutes Low power indicator 4 2 V Power ad...

Страница 7: ...the vicinity of known radio frequency RF transmitting devices and equipment marked with the following symbol Do not drop or physically alter the device or provided components IR emitted from this product may cause eye irritation Do not stare at operating diodes for an extended amount of time Read this guide thoroughly before use Label for X Plus Head Label for X Plus Body WARNING CAUTION Model X P...

Страница 8: ...nty is limited to a period of two years from the purchase date Within this period repairs or exchange of parts that are deemed necessary by the company will be made free of charge This warranty does not cover damage by the following a Misuse abuse or alteration to the product b Damage caused by accident or neglect c Service or repairs made by unauthorized persons LIMITED TWO YEAR WARRANTY WE SHALL...