38
Installation and Assembly
IM-HC 599871 0321 RABS
Attach the Supply Sensor
Attach the supply sensor onto the supply header intake (upstream from
the first circuit).
X
Place the 10 kΩ thermistor inside of the plastic housing for the 10
kΩ thermistor. Place the heat conduction pad between the 10 kΩ
thermistor and the supply header. Use the included cable tie to
attach the supply sensor to the supply header intake. Use scissors
to cut the excess cable tie material.
X
Insert the plug of the supply sensor cable into the control unit
socket, second from the left, until it clicks securely.
X
Press the supply sensor cable into the strain relief recess below the
socket to ensure the housing faceplate closes readily.
Socket for Future Radiant Cooling Function
This socket will be used for a future radiant cooling function.
Connect the WLAN Module
X
Verify that the control unit is unplugged, or that the circuit is shut off.
Then remove the housing faceplate (
Page 35).
X
Insert the plug of the WLAN module cable into the socket of the
control until it clicks securely.
X
Press the WLAN module cable into the strain relief recess below the
socket to ensure the housing faceplate closes readily.