Viega Prevista Dry 8524 Скачать руководство пользователя страница 6

Fig. 1: Components

1 3H concealed cistern

2 Holder for drain elbow

3 Drain elbow

4 Reducer

5 Threaded rods for fixing sanitary objects (gauges for bore hole

180 mm)

6 Screws and dowels for fixing in the floor

7 Screws for fixing in support profile

8 Mounting set for WC ceramic

9 Flushing pipe

10 WC connection socket with lip seal

11 Protective plug for flushing pipe elbow

12 Protective plug for drain elbow DN90

13 Revision shaft cover

14 Corner valve

2.3.2

Compatible components

The WC element is compatible with all common WC ceramics, even

with larger projection (barrier-free).

The WC element can be extended by the following compatible compo‐

nents:

n

Prevista Dry fixing element

n

Prevista Dry fixing set model 8573

Product information

Prevista Dry WC element building project version

6

Содержание Prevista Dry 8524

Страница 1: ...Instructions for Use Prevista Dry WC element building project version for WC flush plates for Prevista Model Year built from 8524 09 2018 INT ...

Страница 2: ...Overview 5 2 3 2 Compatible components 6 2 3 3 Technical data 7 3 Handling 8 3 1 Assembly information 8 3 1 1 Mounting conditions 8 3 1 2 Installation dimensions 9 3 2 Assembly 9 3 2 1 Mounting WC element 9 3 2 2 Connecting concealed cistern 13 3 2 3 Mounting the drain elbow 16 3 2 4 Set and clad the WC element 17 3 2 5 Setting the flush volume 19 3 3 Cleaning and maintenance 21 3 4 Disposal 21 Ta...

Страница 3: ... extend to possible operating instructions The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use 1 2 Labelling of notes Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs DANGER This symbol warns of possible life threatening injury WARNING This sym...

Страница 4: ...many e g DIN DVGW Some passages in the text may refer to technical codes in Europe Germany These should serve as recommendations in the absence of corresponding national regulations The relevant national laws stand ards regulations directives and other technical provisions take priority over the German European directives specified in this manual The information herein is not binding for other cou...

Страница 5: ...ls EN 1996 1 1 Suitable concreted walls DIN 1045 Suitable support profiles DIN 18183 2 2 Intended use 2 2 1 Areas of use The Prevista Dry WC element is suitable for mounting on masonry wall constructions and support profiles pursuant to the regulations in section Ä Regulations from section Fields of application Mounting condi tions on page 5 2 3 Product description 2 3 1 Overview The WC element is...

Страница 6: ...0 WC connection socket with lip seal 11 Protective plug for flushing pipe elbow 12 Protective plug for drain elbow DN90 13 Revision shaft cover 14 Corner valve 2 3 2 Compatible components The WC element is compatible with all common WC ceramics even with larger projection barrier free The WC element can be extended by the following compatible compo nents n Prevista Dry fixing element n Prevista Dr...

Страница 7: ...ccordance with the respective instructions for use 2 3 3 Technical data Small flush volume Factory setting approx 3 l Setting range approx 2 4 l Large flush volume Factory setting approx 6 l Setting range approx 3 5 7 5 l Flush volume Product information Prevista Dry WC element building project version 7 ...

Страница 8: ...allation depth is maximum 200 mm The WC element can only be used in combination with wall hung WCs fixing gauges for bore hole 180 mm The WC element has an R inch water connection The WC element can be extended by a remote flush actuation or by an electronic actuation as well as by sensitive flush plates The cables for these electrical actuation versions must be laid in front of the cladding The c...

Страница 9: ...t Masonry and concreted walls When mounting multiple WC elements with an interval of 500 mm Viega recommends the use of a Prevista Dry support bracket model 8570 48 Observe the instructions for use of the support bracket when mounting Handling Prevista Dry WC element building project version 9 ...

Страница 10: ...rmine and mark the fixing points on the floor n X3 400 mm Drill the holes Insert the dowels INFO Mount the fixing set model 8180 73 pursuant to the instructions for use for the fixing set Loosen the feet of the element using a fork spanner Mounting to a masonry wall 9 9 9 Handling Prevista Dry WC element building project version 10 ...

Страница 11: ...nt in accordance with the on site marking of the upper edge of the finished floor n X 1000 mm Tighten the feet of the element using a fork spanner The element is attached to the wall 9 Handling Prevista Dry WC element building project version 11 ...

Страница 12: ...rough 90 Screw the feet together with the support profile Adjust the construction height of the element in accordance with the on site marking of the upper edge of the finished floor n X 1000 mm Attach the element to the support profiles using the screws sup plied Mounting in metal support profile d 9 Y Y Handling Prevista Dry WC element building project version 12 ...

Страница 13: ...direction Remove the cover plate Place the press connector on the water inlet Press the connection Seal the threaded connectors of the corner valve Screw the corner valve into the thread side of the Steptec rail con nector Handling Prevista Dry WC element building project version 13 ...

Страница 14: ...y seated Use the lock nut to screw the corner valve and the cistern to one another Remove the protective cap from the water supply hose Screw the water supply hose and the corner valve to one another Insert the cover plate into the cistern Handling Prevista Dry WC element building project version 14 ...

Страница 15: ...r plate lock by 90 in a clockwise direction Place the revision shaft on the cover plate To remove the revision shaft press in the fixing clips at the side Handling Prevista Dry WC element building project version 15 ...

Страница 16: ...for the drain elbow Insert the drain elbow to the desired depth Secure the drain elbow using the bow Attach the protective plug of the flushing pipe elbow Put the protective plug of the drain elbow on Handling Prevista Dry WC element building project version 16 ...

Страница 17: ...f the element with a nut Place the protective caps on the threaded rods Corn the gypsum cardboard cladding panel at the revision shaft and at the site protection by applying gentle pressure Cut out the recesses for the site protection the revision shaft and the threaded rods Handling Prevista Dry WC element building project version 17 ...

Страница 18: ... Clad the element with suitable gypsum cardboard cladding panels Handling Prevista Dry WC element building project version 18 ...

Страница 19: ...cistern is freely accessible n The water supply has been shut off n The ceramic has been mounted Fold the tabs forward Lift the drain valve Remove the drain valve through the revision opening Handling Prevista Dry WC element building project version 19 ...

Страница 20: ... Set the large flush volume at the drain valve Set the small flush volume at the drain valve Handling Prevista Dry WC element building project version 20 ...

Страница 21: ...ing valve seals renewed In areas or regions with hard water due to high concentration of calcium or magnesium salts there is the risk of limescale deposits developing on the inlet and drain valves The valves may have to be replaced depending on the extent of the deposits 3 4 Disposal Separate the product and packaging materials e g paper metal plastic or non ferrous metals and dispose of in accord...

Страница 22: ...Viega Technology GmbH Co KG service technik viega de viega com INT 2020 07 VPN180224 ...