Screw on the concealed socket.
3.2
Disposal
Separate the product and packaging materials (e. g. paper, metal,
plastic or non-ferrous metals) and dispose of in accordance with valid
national legal requirements.
Handling
Prevista installation set
10 from 10
Страница 1: ...for Prevista remote flush actuations Model Year built 8640 14 from 03 2019 en_INT Prevista installation set Instructions for Use ...
Страница 2: ...Prevista installation set 2 from 10 ...
Страница 3: ...ups 4 1 2 Labelling of notes 4 1 3 About this translated version 5 2 Product information 6 2 1 Intended use 6 2 1 1 Areas of use 6 2 2 Product description 6 2 2 1 Overview 6 3 Handling 7 3 1 Assembly 7 3 2 Disposal 10 Table of contents Prevista installation set 3 from 10 ...
Страница 4: ...xtend to possible operating instructions The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use 1 2 Labelling of notes Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs DANGER This symbol warns of possible life threatening injury WARNING This symbo...
Страница 5: ... in Germany e g DIN DVGW Some passages in the text may refer to technical codes in Europe Germany These should serve as recommendations in the absence of corresponding national regulations The relevant national laws stand ards regulations directives and other technical provisions take priority over the German European directives specified in this manual The information herein is not binding for ot...
Страница 6: ...tallation set is required for the installation of WC remote flush actuations for Prevista 2 2 Product description 2 2 1 Overview Fig 1 Scope of delivery 1 Concealed socket 2 Screws and plates for fixing 3 Protective pipe Product information Prevista installation set 6 from 10 ...
Страница 7: ...s 3 m Factor in at least 0 25 m for the cistern n The distances conform to the specifications Fasten the screws and securing plates in the concealed socket Push through the concealed socket at the pre punched location N N Handling Prevista installation set 7 from 10 ...
Страница 8: ...Route the empty pipe through the shower WC connection into the cistern WC element construction height 820 mm without shower WC con nection Insert the empty pipe into the cistern from below Cut in the cap crosswise for the free water connection Drill the recess for the empty pipe in the gypsum cladding panel Route the empty pipe outside Handling Prevista installation set 8 from 10 ...
Страница 9: ... template Position the template on the gypsum cladding panel Route the empty pipe through the concealed socket Push the concealed socket onto the template and corn the gypsum cardboard cladding panel by applying gentle pressure Cut the recesses for the concealed socket Insert the concealed socket into the gypsum cladding panel Handling Prevista installation set 9 from 10 ...
Страница 10: ...socket 3 2 Disposal Separate the product and packaging materials e g paper metal plastic or non ferrous metals and dispose of in accordance with valid national legal requirements Handling Prevista installation set 10 from 10 ...