Instructions for Use
Electronics accessory set
For electronic WC flush plates for Prevista
Model
Year built (from)
8655.11
03/2019
INT
Страница 1: ...Instructions for Use Electronics accessory set For electronic WC flush plates for Prevista Model Year built from 8655 11 03 2019 INT...
Страница 2: ...5 2 4 General notes 6 2 5 Product description 7 2 5 1 Overview 7 2 5 2 Technical data 8 2 5 3 Connection diagram 8 2 6 Accessories 9 3 Handling 10 3 1 Assembly information 10 3 1 1 Mounting conditions...
Страница 3: ...ction does not extend to possible operating instructions The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use 1 2 L...
Страница 4: ...or in Germany e g DIN DVGW Some passages in the text may refer to technical codes in Europe Germany These should serve as recommendations in the absence of corresponding national regulations The rele...
Страница 5: ...e Notice Regulations applicable in Ger many Electrical approvals EN 60950 Electrical approvals EN 60335 Electrical approvals EN 61558 2 2 Safety advice DANGER Danger due to electrical current An elect...
Страница 6: ...ildren do not play with this product n A disconnect device with a contact opening width that fulfils the con ditions of overvoltage category III for full separation in accordance with the installation...
Страница 7: ...escription The marked product must not be disposed of as household waste 2 5 Product description 2 5 1 Overview 1 Electronic drive unit 2 Power pack 3 Terminal Product information Electronics accessor...
Страница 8: ...gulations from sec tion Technical data on page 5 Motor Voltage V Current mA 6 5 500 2 5 3 Connection diagram 7 _ 7 EBUB EBUB Fig 1 Connection diagram power pack WC flush plate for Prevista 1 Power pac...
Страница 9: ...2 metre cable for the extension of the power supply Use a maximum of two extension cables with the power pack 4 75 meter total length Connection cable model 8570 55 3 meter cable for external flush ac...
Страница 10: ...wer pack cable can be extended to a length of 4 75 metres two extension cables Optional accessories on page 9 X1 X2 X3 Fig 2 Installation position of the power pack X1 max 0 75 m X2 max 2 75 m with an...
Страница 11: ...e 5 Viega recommends installing the power pack outside of the protected zones 0 2 3 1 2 Required material and tools The following material is required for mounting n if necessary empty pipe from power...
Страница 12: ...n ON The assignment of the DIP switches n Switches 1 4 define the flush volume n Switches 5 7 define the interval of the Viega Hygiene function n Switch 8 defines the flush volume of the Viega Hygiene...
Страница 13: ...rogram 5 3 5 3 0 1 0 1 Program 6 4 5 3 0 1 1 0 Program 7 7 5 3 0 1 1 1 Program 8 4 5 4 1 0 0 0 Program 9 6 4 1 0 0 1 Program 10 7 5 4 1 0 1 0 Viega Enabling the Hygiene function and setting the interv...
Страница 14: ...n death n Only allow electrical work to be carried out by qualified electricians n Always de energise the connection cable before work is commenced Observation of the prescribed connection sequence is...
Страница 15: ...pack complies with the require ments in acc with Chapter 3 1 1 Mounting conditions on page 10 n The connection cable is de energised Remove the shaft cover Turn the cover plate lock 90 in anti clockw...
Страница 16: ...the terminals INFO Use the cable feedthrough Route the connection cable from the power pack through the empty pipe into the cistern Guide the connection cable out through the cistern Turn the cover p...
Страница 17: ...unit engage in the mechanism Turn the cover plate 180 Connect the clip of the mechanism and the drive unit to the eye Apply the silicon grease to all drive unit connections d Y Handling Electronics ac...
Страница 18: ...the power pack Guide the long cable of the drive unit forward through the cover plate Insert the cover plate into the cistern Turn the cover plate lock by 90 in a clockwise direction Insert the shaft...
Страница 19: ...death n Only allow electrical work to be carried out by qualified electricians n Always de energise the connection cable before work is commenced Observation of the prescribed connection sequence is...
Страница 20: ...uire ments in acc with Chapter 3 1 1 Mounting conditions on page 10 n The connection cable is de energised Remove the shaft cover INFO In the description of the following steps the cistern is shown in...
Страница 21: ...ulation on the cables Push the cables into the terminals INFO Use the cable feedthrough Route the connection cable from the power pack through the empty pipe into the cistern Guide the connection cabl...
Страница 22: ...t on the mechanism Let the drive unit engage in the mechanism Connect the clip of the mechanism and the drive unit to the eye Apply the silicon grease to all drive unit connections Y Handling Electron...
Страница 23: ...he flushing station Place the mechanism with the drive unit into the rear of the cover plate Hang the mechanism in the tab of the drain valve Guide the long cable of the drive unit forward through the...
Страница 24: ...sal Separate the product and packaging materials e g paper metal plastic or non ferrous metals and dispose of in accordance with valid national legal requirements Electronic components and batteries m...