Only in connection with Prevista Dry WC element 8521.32,for ceramic ≤ 28 kgModel
Year built:
8570.51
from 03/2019
en_INT
Gas pressure spring ≤ 28 kg
Instructions for Use
Страница 1: ...Only in connection with Prevista Dry WC element 8521 32 for ceramic 28 kg Model Year built 8570 51 from 03 2019 en_INT Gas pressure spring 28 kg Instructions for Use ...
Страница 2: ...Gas pressure spring 28 kg 2 from 10 ...
Страница 3: ... notes 4 1 3 About this translated version 5 2 Product information 6 2 1 Intended use 6 2 1 1 Areas of use 6 3 Handling 7 3 1 Assembly 7 3 1 1 Replace gas pressure spring 7 3 1 2 Preparing gas pressure spring for disposal 8 3 2 Disposal 10 Table of contents Gas pressure spring 28 kg 3 from 10 ...
Страница 4: ...xtend to possible operating instructions The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use 1 2 Labelling of notes Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs DANGER This symbol warns of possible life threatening injury WARNING This symbo...
Страница 5: ... in Germany e g DIN DVGW Some passages in the text may refer to technical codes in Europe Germany These should serve as recommendations in the absence of corresponding national regulations The relevant national laws stand ards regulations directives and other technical provisions take priority over the German European directives specified in this manual The information herein is not binding for ot...
Страница 6: ...as of use The gas pressure spring is exclusively suitable for the height adjustable Prevista Dry WC element model 8521 32 The gas pressure spring is used to lift and lower WC ceramic up to 28 kg Product information Gas pressure spring 28 kg 6 from 10 ...
Страница 7: ...will touch To avoid touching limit the lowering of the WC possible up to a max of 20 mm Place a maximum of five 4 mm spacer washers under the piston rod of the gas pressure spring Requirements n The WC ceramic is at the lowest position n Following components are removed WC ceramic Cover plate Actuating button Hydraulic actuation cover frame Remove the gas pressure spring by unscrewing the top and ...
Страница 8: ...actuation n Cover plate n WC ceramic 3 1 2 Preparing gas pressure spring for disposal WARNING High pressure The gas is the gas pressure is highly pressurised During drilling there is a risk of injury due to flying metal fragments and oil Wear eye and face protection and protective clothing Ensure that there are no persons in the danger zone in front of and behind the piston rod Do not cut off the ...
Страница 9: ...5 40 WARNING The gas is the gas pressure spring is highly pressur ised During drilling there is a risk of injury due to flying metal fragments and oil Using a 23 mm drill drill slowly at point X2 until gas escapes Using a 23 mm drill drill slowly at point X1 until pressure drops and oil becomes accessible Pour out the oil into a suitable container ð Now the piston rod can be easily moved by hand I...
Страница 10: ...osal Separate the product and packaging materials e g paper metal plastic or non ferrous metals and dispose of in accordance with valid national legal requirements Handling Gas pressure spring 28 kg 10 from 10 ...