The radius of the hydraulic actuation must be at least 50 mm.
This prevents the hydraulic actuation from buckling.
3.2.9
Limiting the setting range
The length of the gas pressure spring, and therefore also the setting
range of the WC, can be limited by max. 20 mm if the upper edge of the
finished floor is higher than intended.
The cover plate can be prevented from touching by using spacer
washers (4 mm each).
A maximum of five spacer washers may be used.
Requirements:
n
The WC ceramic is at the lowest position.
n
Following components are removed:
n
WC ceramic
n
Cover plate
n
Actuating button / hydraulic actuation
n
cover frame
▶
Remove the gas pressure spring by unscrewing the top and bottom
5 mm Allen screw.
ı3
Handling
Prevista Dry WC element ceramic height individually adjustable
35