background image

12 Protective plug for drain elbow DN90

13 Revision shaft cover

14 Corner valve

2.2.2

Compatible components

The WC element is compatible with all common WC ceramics, even

with larger projection (barrier-free).

The WC element can be extended by the following compatible compo‐

nents:

n

Prevista Dry fixing element

n

Prevista Dry fixing set model 8573

n

Fixing set model 8180.73

n

Accessory set connection electronic model 8655.11

Mount the components in accordance with the respective instructions

for use.

2.2.3

Technical data

Small flush volume

Factory setting

approx. 3 l

Setting range

approx. 2–4 l

Large flush volume

Factory setting

approx. 6 l

Setting range

approx. 3.5–7.5 l

2.3

Accessories

You require the Prevista Pure standing bracket model 8570.54 to enable

the stand-alone mounting of the Prevista Pure WC block.

Flush volume

Standing bracket for stand-alone mounting

Product information

Prevista Pure WC block 3H

7 from  21

Содержание 8516

Страница 1: ...for WC flush plates for Prevista walling in and around Model Year built 8512 from 03 2019 en_INT Prevista Pure WC block 3H Instructions for Use ...

Страница 2: ...Prevista Pure WC block 3H 2 from 21 ...

Страница 3: ...2 2 2 Compatible components 7 2 2 3 Technical data 7 2 3 Accessories 7 3 Handling 8 3 1 Assembly information 8 3 1 1 Installation dimensions 8 3 2 Assembly 9 3 2 1 Mounting the WC block 9 3 2 2 Connecting concealed cistern 12 3 2 3 Mounting the drain elbow 15 3 2 4 Setting up and bricking in the WC block 17 3 2 5 Setting the flush volume 19 3 3 Cleaning and maintenance 21 3 4 Disposal 21 Table of ...

Страница 4: ...oes not extend to possible operating instructions The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use 1 2 Labelling of notes Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs DANGER This symbol warns of possible life threatening injury WARNING T...

Страница 5: ... in Germany e g DIN DVGW Some passages in the text may refer to technical codes in Europe Germany These should serve as recommendations in the absence of corresponding national regulations The relevant national laws stand ards regulations directives and other technical provisions take priority over the German European directives specified in this manual The information herein is not binding for ot...

Страница 6: ...can generally be used with all types of WC ceramic 2 2 Product description 2 2 1 Overview 1 3H concealed cistern 2 Reducer 3 Holder for drain elbow 4 Drain elbow 5 Wall mounting 6 Threaded rods for fixing sanitary objects gauges for bore hole 180 or 230 mm 7 Screws for fixing in support profile 8 Mounting set for WC ceramic 9 Flushing pipe 10 WC connection socket with lip seal 11 Protective plug f...

Страница 7: ...el 8180 73 n Accessory set connection electronic model 8655 11 Mount the components in accordance with the respective instructions for use 2 2 3 Technical data Small flush volume Factory setting approx 3 l Setting range approx 2 4 l Large flush volume Factory setting approx 6 l Setting range approx 3 5 7 5 l 2 3 Accessories You require the Prevista Pure standing bracket model 8570 54 to enable the...

Страница 8: ...3 Handling 3 1 Assembly information 3 1 1 Installation dimensions Fig 1 Dimensional drawing Handling Prevista Pure WC block 3H 8 from 21 ...

Страница 9: ...y 3 2 1 Mounting the WC block Remove the protection box Break the locking clips off the wall mountings Push the wall mountings into the element Insert the locking clips Handling Prevista Pure WC block 3H 9 from 21 ...

Страница 10: ...nce with the on site marking of the upper edge of the finished floor X 1000 mm Mark the fixing points Drill the holes Insert the dowels Tighten the WC block via the mounting brackets using a fork spanner size 13 9 Handling Prevista Pure WC block 3H 10 from 21 ...

Страница 11: ...Attach rail to the wall Attach each of the cisterns to the Steptec rail connector using two connection pieces Line mounting Handling Prevista Pure WC block 3H 11 from 21 ...

Страница 12: ...ockwise direction Remove the cover plate Place the press connector on the water inlet Press the connection Seal the threaded connectors of the corner valve Screw the corner valve into the thread side of the Steptec rail con nector Handling Prevista Pure WC block 3H 12 from 21 ...

Страница 13: ... corner valve into the cistern INFO Ensure the corner valve is correctly seated Use the lock nut to screw the corner valve and the cistern to one another Remove the protective cap from the water supply hose Screw the water supply hose and the corner valve to one another Handling Prevista Pure WC block 3H 13 from 21 ...

Страница 14: ...o the cistern Turn the cover plate lock by 90 in a clockwise direction Place the revision shaft on the cover plate To remove the revision shaft press in the fixing clips at the side Handling Prevista Pure WC block 3H 14 from 21 ...

Страница 15: ...3 2 3 Mounting the drain elbow Insert the mounting bracket for the drain elbow Fill up the bottom part of the element with mortar Replace the protection box Handling Prevista Pure WC block 3H 15 from 21 ...

Страница 16: ...Insert the drain elbow Fasten the drain elbow using the bow Attach the protective plug of the flushing pipe elbow Fit the protective plug of the drain elbow Handling Prevista Pure WC block 3H 16 from 21 ...

Страница 17: ... the threaded rods in front of the element with a nut For 230 mm gauge for bore hole Counter the threaded rods in front of and after the element with a nut Push the protective caps onto the threaded rods Brick in the WC block The tiling format must be at least 10 mm min 10 Handling Prevista Pure WC block 3H 17 from 21 ...

Страница 18: ...Tile the WC block Handling Prevista Pure WC block 3H 18 from 21 ...

Страница 19: ... n The cistern is freely accessible n The water supply has been shut off n The ceramic has been mounted Fold the tabs forward Lift the drain valve Remove the drain valve through the revision opening Handling Prevista Pure WC block 3H 19 from 21 ...

Страница 20: ...Set the large flush volume at the drain valve Set the small flush volume at the drain valve Handling Prevista Pure WC block 3H 20 from 21 ...

Страница 21: ...nd filling valve seals renewed In areas or regions with hard water due to high concentration of calcium or magnesium salts there is the risk of limescale deposits developing on the inlet and drain valves The valves may have to be replaced depending on the extent of the deposits 3 4 Disposal Separate the product and packaging materials e g paper metal plastic or non ferrous metals and dispose of in...