Lead empty pipe from the switch or button into the concealed cis-
tern, to connect the concealed socket and concealed cistern.
Positioning of the cistern power pack
n
X1= max. 0.75 m
n
X2= max. 2.75 m with an extension cable, 1 x article number 628 505
n
X3= max. 4.75 m with two extension cables, 2 x article number 628
505
3.2.4
Rounding off jobs
Single clad pre-wall: Clad with 12.5 mm wide IFGP or 12 mm wide
Aqua-KS cladding panels.
When doing so, make sure that no abutting edges converge.
Grout the abutting edges and joints with a suitable filler.
Observe the instruction manual for the cladding panels for more
information.
Reserve a recess for the shower WC (AquaClean). In addition,
observe the manufacturer's instructions.
3.2.5
Setting the flush volume
Immediate re-flushing of the flush volume is possible at the
factory settings.
The WC module is factory-set at a small flush volume of approx. 3 l. The
small flush volume can be set at three levels: approx. 3 l / 3.5 l / 4 l.
Remove the drain valve from the concealed cistern.
X1
X2
X3
Small flush volume
Handling
Viega Steptec WC module with empty pipe for shower WC (AquaClean)