Connect the cable from the programming contact onto the control.
Hold the magnetic key in front of the programming contact.
ð
In the following, signals sound to show which setting is active.
Remove magnetic key to enable setting.
The following values can be set by removing the magnetic key:
Remove magnetic key after
Setting
8th acoustic signal
flush volume 6 l (fac-
tory setting, if is
active)
9th acoustic signal
flush volume 6 l
10. Acoustic signal
flush volume 9 l
ð
A double acoustic signal is sounded as confirmation. The set-
ting has been successfully changed.
Handling
WC flush actuation
36 from 42
Содержание 8350.33