![Viega 4921.4 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/viega/4921-4/4921-4_instructions-for-use-manual_1016556011.webp)
3.1.3
Tools and materials
n
Material for securing the drain
3.2
Assembly
3.2.1
Connecting the drain
The connection to the wastewater system must be completed before
the drain can be installed in the floor construction. Proceed as follows:
Requirements:
n
A pipe to the planned drainage position is already in place for the
connection to the wastewater system.
n
The drainpipe has an internal sealing lip.
Align drain socket on the ball joint.
Push the drain socket into the drainpipe completely.
The connection to the inlet must first be made to be able to mount the
drain. Proceed as follows:
Requirements:
n
Inlet pipe has been mounted.
Unscrew the union nut from the drain inlet.
Required material
Connecting to the wastewater system
Fig. 2: Insert drainpipe
Connecting the inlet
Handling
Advantix bathroom drain