VIDITECH Vibrodiag Скачать руководство пользователя страница 1

 

 

www.viditech.eu 

rev. 1.7 

[email protected] 

 

 

www.ViDiTech.eu 

 

Vibrodiag 

FW 0.04.41 and higher 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

Содержание Vibrodiag

Страница 1: ...www viditech eu rev 1 7 sales viditech cz www ViDiTech eu Vibrodiag FW 0 04 41 and higher...

Страница 2: ...MENU 8 5 1 INSTRUMENT SETUP 9 5 2 SENSOR SETUP 10 5 3 LIMITS SETUP 10 6 DATABASE ROUTES 11 6 1 MEASURING PLACES 11 6 2 ROUTES 11 7 MEASURING 13 7 1 ROUTE MEASURING 13 7 2 ANALYSIS 14 7 2 1 Velocity an...

Страница 3: ...to 60g Range of measured velocities up to 200 m s 1 using provided sensors RMS vibration measurement according to ISO 2373 Balancing wizard Threshold recorder Periodical recorder ICP acceleration sens...

Страница 4: ...ch TFT Display diagonal 3 4 Memory card type SD PCconnection USB 2 0 2 2 Accuracy Total vibrations at80 Hz 2 1 digit within range 1 5 000 Hz 10 1digit at limit frequencies 10 20 1digit Frequencycharac...

Страница 5: ...nsor sensitivity 100 mV g 20 Range of measured accelerations 60 g Protection IP67 Chassis material stainless steel Dimensions 25x66 mm diameter height Weight 125 6 g Connector M12 Attachment outer thr...

Страница 6: ...channel A 5 Socket for ICP sensor channel B 6 Socket for revolution sensor 7 Socket for supply connector 8 Socket for USB connector 9 SD card slot 10 Power supply adapter 15 V 1 6 A 11 ICP sensor cabl...

Страница 7: ...ts the instrument stabilizes the filters for only 2 s 3 1 2 ICP sensors ICP sensors are connected with the unit using shielded cables with colour distinguished connectors for each channel The only and...

Страница 8: ...m Analysis Balancing Recorder VibroGuide Order 1 Hz 1 kHz velocity 500Hz 5kHz acceleration Custom Saved data Run up coast down Run up Coast down Saved data Single plane Dual plane N planes Saved data...

Страница 9: ...equently it is possible to save individual measurements which point to the selected places routes Item Measuring contains all options of measuring allowed by the purchased licences see Setup i VibroGu...

Страница 10: ...erm instrument non use there is a danger of set date and time loss After power resupply in form of charged battery or connected charger random date and time are set and is therefore necessary to updat...

Страница 11: ...imits setup Main menu Setup Limits Limits are used to advise of detected increased values of vibration velocity on the diagnosed object These increased vibrations refer to the current machine state Li...

Страница 12: ...by place definition of Machine using icon and place parameters setup using icon with switching screens left right see fig 10 Here it is possible to set parameters of channel A and B and predefined op...

Страница 13: ...sales viditech cz 12 Fig 9 a Factory definition b Machine definition c Machine information Fig 10 a Place definition b Place setup c Place setup Fig 11 a Route definition b Adding place to route c Di...

Страница 14: ...performed by tapping on the box next to the relevant channel Bar graphs change colour according to the level of signal in reference to the set limits L1 L2 If RMS velocity exceeds threshold L1 bar gra...

Страница 15: ...requency and amplitude see fig 14b After specifying the relevant value in the table row the setting will change back to graph and mark the selected point using a cursor Values in the table and graph a...

Страница 16: ...sales viditech cz 15 Fig 13 a Analysis selection b Channel selection c Running analysis Fig 14 a Analysis display b Table of values c Optional analysis Fig 15 a Saved analyses b Saved analysis c Addi...

Страница 17: ...ther with the current vibration velocity values are displayed in the bottom part of the screen After revolutions set in final state run up to maximum coast down to minimum it is necessary to end the r...

Страница 18: ...Personnel without appropriate practice should not conduct these measurements 7 4 1 Balancing in single plane Main menu Measuring Balancing Single plane This option is used for balancing thin rotating...

Страница 19: ...ancing weights it is necessary to remove the test weight A control may be done by performing a new balancing It is possible to return by one step back leave and save result in the balancing process Fi...

Страница 20: ...s sense it is the revolution frequency Test Run Sizing counterweight must be performed with a running test weight Test weights are attached to balancing wheels the weight and the position must be ente...

Страница 21: ...er the position of the accelerometer towards the speed sensor The position is then noted in the balancing results 3 weights of the same weight should be present on the grinding wheel which are spaced...

Страница 22: ...ocess can return one step back leave save the result and store parameters Fig 19 a first run b the calculation of weights c the result of balancing 7 4 4 Displaying saved balancing Main menu Measure B...

Страница 23: ...VIBRODIAG www viditech eu sales viditech cz 22 Fig 18 a Saved data b Informative data c Measured results...

Страница 24: ...hreshold absolutely in mm s or relatively by entering percent of range The numerical value of threshold is entered by tapping on the box marked Threshold It is possible to record Velocity analysis Acc...

Страница 25: ...02 30 and for Vibration 00 00 02 fig 21a After analysis initiation the following are displayed time till end of one period and saving of first and subsequently the following record If the symbol is in...

Страница 26: ...nnel sensing are preset Maximal number of analyses that can be loaded for the threshold recorder is 10 only 5 of them are displayed in the graph Information about the current selected analysis are sho...

Страница 27: ...AG www viditech eu sales viditech cz 26 Fig 22 a Saved data from rec b Threshold rec vibrations c Threshold rec analyses Fig 23 a Adding another analysis b Periodical rec vibrations c Periodical rec a...