66250935-EN - V1.2 - 15/01/16
2
Kristallo Series
Art. KR-AV - Installation instructions
OPERATION
To call the apartment
Press the button :
• The LED turns OFF and the LED starts flashing slowly emitting a low volume beep each time the LED turns ON.
• When the apartment answers, the LED flashes faster and the conversation is open.
• When the conversation is closed, both the LEDs are temporarily turned OFF then turned ON again.
In case of no answer, the call stops automatically after 40 seconds approx while in case of answer if the conversation is not closed
by the user the call will terminate automatically after 60 seconds.
To switch ON the stair light
Press the button :
• The LED flashes quickly during the time that the “LGT” output is active.
The function requires the connection of a relay that must be enabled by the “LGT” active low output.
To open the door by the door open code
Enter the 8 digits door opening code by the four numeric buttons , , and .
• The LED turns off.
The LED turns off then the unit emits a beep and the LED flashes each time a numeric button is pressed.
If the entered code is correct, the LED flashes quickly 3 times, the unit emits 3 short beeps and the “REL” output is enabled for the
programmed time while if the code is wrong the LED remains off and 3long beep are emitted.
The function requires the connection of a relay that must be enabled by the “REL” active low output.
PROGRAMMING & ADJUSTMENTS
Programming options are:
• The Phone ID (address) of the local videophone to call when the button is pressed (10 ways dip-switch bank, switches from
1 to 8).
• The door opening time for the electric lock (switch 9).
• The door opening code (through the numeric buttons , , and ).
LOCAL VIDEOPHONE PHONE ID SETUP
Use the first 8 dip-switches of the 10 way dip-switch bank to set the PHONE ID for the local videophone. Each switch corresponds to
one bit which can have a value 0 (OFF) or 1 (ON). Each bit corresponds to a decimal weight depending on the position: Switch 1 =
decimal 1, 2=2, 3=4, 4=8, 5=16, 6=32, 7=64, 8=128.
I.E.
to set the address 37, put switches 1, 3 and 6 on (1+4+32=37).
SWITCHES
DECIMAL WEIGHT
ADDRESS
8
7
6
5
4
3
2
1
128
64
32
16
8
4
2
1
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
0
0
0
0
0
0
0
1
1
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
0
0
0
0
0
0
1
0
2
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
0
0
0
0
0
0
1
1
3
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
0
0
0
0
0
1
0
0
4
OFF
OFF
ON
OFF
OFF
ON
OFF
ON
0
0
1
0
0
1
0
1
37
ON
OFF
ON
ON
OFF
ON
OFF
OFF
1
0
1
1
0
1
0
0
180
DOOR OPENING TIME SETUP
The switch 9 sets the door opening time : OFF= 2 seconds, ON= 6 seconds.
DOOR OPEN CODE SETUP
To setup the door opening code proceed as follows:
1. With the unit in stand-by (LEDs and ) turned ON, enter the 8 digit engineer’s code (factory default “11111111” eight times
one).
2. Both the LEDs and start flashing, enter a new engineer’s code (8 digits) or confirm the old one entering it (8 digits) again.
3. Enter the new door open code (8 digits) using the buttons , , and .
To restore the engineer’s code to the factory default, power off the unit put ON switch 10 and power up the unit again then
put OFF switch 10. The engineer’s code is restored to “11111111” eight times one.
Art. KR-AV
Indoor Digital A/V door panel for VX2200