PROGRAMMING
The programming of the module is carried out through the VIDEX IP Wizard software. There are some adjustments available directly
on the module:
• Microphone volume through the relevant trimmer;
• Speaker volume through the relevant trimmer;
• RS-485 connection termination.
For the module programming refer to the section VIDEX IP Wizard.
CONNECTION
EIA/TIA-568A
1
2
3
4
5
6
7
8
EIA/TIA-568A
TX+
TX−
RX+
RX−
4533 signals
RJ-45 pin
TX+
PIN 1 - White-green
TX
–
PIN 2 - Green
RX+
PIN 3 - White-orange
RX
–
PIN 6 - Orange
EIA/TIA-568B
1
2
3
4
5
6
7
8
EIA/TIA-568B
TX+
TX−
RX+
RX−
4533 signals
RJ-45 pin
TX+
PIN 1 - White-orange
TX
–
PIN 2- Orange
RX+
PIN 3 - White-green
RX
–
PIN 6 - Green
OTHER STANDARD CABLES
1
2
3
4
5
6
7
8
TX+
TX−
RX+
RX−
4533 signals
RJ-45 pin
TX+
PIN 1
Twisted pair
TX
–
PIN 2
RX+
PIN 3
Twisted pair
RX
–
PIN 6
J2 AND J1 JUMPERS BACKLIT LEDS SETTINGS
For proper functioning please set
J2
and
J1
jumpers of any con-
nected button expansion module Art. 404X as shown in the ta-
ble aside.
J2
J1
B A
B A
OPERATION
The system operation is supported by the built-in LED.
• When a visitor press a call button the units emits an intermittent deep call tone and in correspondence with the tone the
red
) until the resident answer or the programmed call time expires.
• If the called indoor station is busy the
red LED flashes (
) 4 times quickly and the unit emits a deep tone on each flash.
• When the resident answers, the
yellow LED (
) illuminates and remains illuminated until the conversation terminates.
• If the resident open the door, the
green illuminates (
) for the programmed door opening time.
ERROR MESSAGES
The LED
is used also to provide error messages concerning system misfunctions:
• A fast flashing LED shows connection to the push notification service is being made. This should only be temporary; if this persists then
there is something not working correctly;
• Slow flashing means that the gateway set cannot be reached;
• fixed on means that the SIP server cannot be reached or connection not allowed because of wrong credentials.
Fig. 3
Call in progress
Fig. 4
Calling a busy indoor
station
Fig. 5
The conversation is in
progress
Fig. 6
Door opening