Страница 2: ......

Страница 3: ...OPHONE FOR VX2300 2 WIRE SYSTEM 8 ART 5488 11 HANDS FREE VIDEOMONITOR SPECIFIC FOR VX2300 11 ART 317 15 FOUR WAY DISTRIBUTION BOX 15 ART 2301 4 16 ENTRANCES EXCHANGER FOR VX2300 DIGITAL SYSTEMS 16 ART 2305 17 EXTENSION RELAY FOR VX2300 DIGITAL SYSTEMS 17 ART 2321 2321 P 18 POWER SUPPLIES FOR VX2300 18 GENERAL DIRECTIONS FOR INSTALLATION 19 ...

Страница 4: ...e electric lock 3 contacts common normally open and normally closed It can work also as capacitor discharge to supply directly the electric lock The call buttons from 1 to a maximum of 2 depending on the module version The illumination LEDs for the card name holder The camera comprised of illumination LEDs Module Details a Camera with illumination LEDs b Loudspeaker c Card name holder d Call push ...

Страница 5: ...rmally open contact BUS Bus connection terminals C Door open relay normally closed contact PTE Push to exit active low input C Electric lock capacitor discharge output GND Ground VAUX 35Vdc power supply input if used the module is powered locally and not from the BUS GND Ground NC Door open relay normally closed contact To use the electric lock with capacitor discharge make a short between C and C...

Страница 6: ... ON position red LED ON the service will be automatically f Call tone volume control 3 levels DIP SWITCHES AND JUMPERS FIG 2 SW1 Switches from 1 to 7 are used for unit address from 1 to 127 binary coded Last switch 8 is not used SW2 Switches 2 3 and 4 are used to set privacy duration time The switch 1 is not used SW3 Switches 1 2 and 3 are used to for intercommunication settings The switch 4 is no...

Страница 7: ...s the address value is Eg extension 10 ten times 12 twelve times etc SIGNALS ON CONNECTION TERMINALS Signal Description BUS BUS Bus contacts LED Door open LED ground signal input LED Door open LED power supply input GND Ground signal GND Local Bell contact AL Alarm input not implemented LB Local Bell contact put a push button between this terminal and the relevant GND terminal SPECIFICATION Housin...

Страница 8: ...uses the Art 4303N plus the Art 4330N pressing this button during a conversation switches the video signal coming from the camera module to the video signal coming from the camera module input for external camera c Activate bus relay board Art 2305 push button To activate a bus relay pick up the handset and press as many times as the address value of the relay d Service push button e Privacy ON OF...

Страница 9: ...TIME Switches Status Privacy Mode switch 2 Privacy Duration switches 3 4 4 3 2 1 OFF OFF 15 minutes OFF ON 1 hour ON OFF 4 hours ON ON OFF The privacy duration time is set by the switches 3 and 4 After enabled the privacy service is disable when the time set expire or the relevant button is pressed again 8 hours ON No privacy time expiration the privacy service is enabled or disabled only by the r...

Страница 10: ...carried out by the dip switches located on the rear of the videophone Controls Call tone volume contrast and brightness Power Supply Supplied by the BUS line Working Temperature 10 50 ºC CUSTOMER SUPPORT INFORMATION All Countries Customers UK Customers VIDEX Electronics S p A www videx it technical videx it Tel 39 0734 631669 Fax 39 0734 632475 VIDEX Security LTD www videx security com Tech Line 0...

Страница 11: ...ch off Simplex button Pressing and holding the button for more than 3 seconds will switch the videomonitor into SIMPLEX speech mode Press and hold the button to speak to the caller The LED 2 will flash rapidly release the button to listen The LED 2 will flash slowly If the button is not pressed for 10 seconds the videomonitor will switch off The videomonitor will revert to duplex speech when anoth...

Страница 12: ...is 37 Switches Status Binary Code Decimal Weight 7 6 5 4 3 2 1 64 32 16 8 4 2 1 Ad dress OFF OFF OFF OFF OFF OFF ON 0 0 0 0 0 0 1 1 OFF OFF OFF OFF OFF ON OFF 0 0 0 0 0 1 0 2 OFF OFF OFF OFF OFF ON ON 0 0 0 0 0 1 1 3 OFF OFF OFF OFF ON OFF OFF 0 0 0 0 1 0 0 4 OFF ON OFF OFF ON OFF ON 0 1 0 0 1 0 1 37 ON ON ON ON ON ON ON 1 1 1 1 1 1 1 127 Note The maximum number of units allowed is 100 but the add...

Страница 13: ...inutes ON OFF 1 hour OFF ON 4 hours ON ON 8 hours VIDEOMONITOR CONNECTION BOARD ART 5980 Fig 3 SIGNAL ON CONNECTION TERMINALS Terminal Signal Description 1 GND Ground 2 BUS1 Bus input 3 4 BUS2 Bus input 5 S1 Terminal controlled by the S1 button close to GND until the button is pressed 6 LED Auxiliary LED power supply input 12Vdc 7 S2 Terminal controlled by the S2 button close to GND until the butt...

Страница 14: ...ophone Fig 4 and push down as suggested by the pointers in Fig 3 the videophone will lock into place To remove the videophone hold it firmly and push the unit in an upward direction until the videophone h unlocks from the mounting plate c SPECIFICATION Housing Mounting 5000 Series Videophones mounting plate plus connection board Push buttons Yes 6 Programming Yes carried out by the dip switches lo...

Страница 15: ...UT 4 is not used BL Close Open bus through output If the distributor is the last move to close otherwise leave open AMPLIFICATION Set the requested level of amplification choosing between low medium and high SPECIFICATION Housing Mounting Plastic box 70x110x30mm direct wall mounting Push Buttons N A Programming N A Controls Outputs amplification 3 levels Power Supply Supplied by the BUS line Worki...

Страница 16: ...irectly to the wall Push Buttons N A Programming N A Controls N A Power Supply From specific power supply or from the bus Working Temperature 10 50ºC CUSTOMER SUPPORT INFORMATION All Countries Customers UK Customers VIDEX Electronics S p A www videx it technical videx it Tel 39 0734 631669 Fax 39 0734 632475 VIDEX Security LTD www videx security com Tech Line 0191 224 3174 Fax 0191 224 1559 The pr...

Страница 17: ...f the videophone will operate the relay one while pressing 4 times will operate the relay two EXTENSION RING SWITCH 8 ON When the unit is set in this mode the switches from 1 to 7 8 is not used are used to set the address of the unit the address of the unit is set by the same way of the videophone or intercom refer to intercom videophone SW1 settings When is called the address set for the unit the...

Страница 18: ...g the retaining screws Fix the power supply to a DIN bar or directly to the wall using two expansion type screws Switch off the mains using the circuit breaker mentioned above and then make the connections as shown on the installation diagrams Check the connections and secure the wires into the terminals Replace the terminal covers and fix them using the relevant screws When all connections are ma...

Страница 19: ...farthest door station or between the power supply and the farthest videophone In case of housing project where it is necessary to reutilize the existing cables that could be cabled together with mains or other power cables check in advance the practicability of the system if the system cables are cabled together mains or other power cables the system is directly exposed to electromagnetic interfer...

Страница 20: ...PrtCode ESVK_ENG_1 3 Pag 20 24 23 10 2008 Rev 1 3 ESVK 1 ONE WAY TWO WIRE VIDEO DOOR ENTRY KIT ...

Страница 21: ...PrtCode ESVK_ENG_1 3 Pag 21 24 23 10 2008 Rev 1 3 CESVK 1 ECLIPSE ONE WAY TWO WIRE VIDEO DOOR ENTRY KIT ...

Страница 22: ...PrtCode ESVK_ENG_1 3 Pag 22 24 23 10 2008 Rev 1 3 ESVK 2 TWO WAY TWO WIRE VIDEO DOOR ENTRY KIT ...

Страница 23: ...PrtCode ESVK_ENG_1 3 Pag 23 24 23 10 2008 Rev 1 3 CESVK 2 ECLIPSE TWO WAY TWO WIRE VIDEO DOOR ENTRY KIT ...

Страница 24: ...rity com e mail info videx security com Northern UK office VIDEX SECURITY LTD Unit 4 7 Chillingham Industrial Estate Chapman Street NEWCASTLE UPON TYNE NE6 2XX Phone 44 0870 3001240 Tech Line 44 0191 224 3174 Fax 44 0191 224 1559 Greece office VIDEX HELLAS Electronics 48 Filolaou Str 11633 Athens Phone 30 210 7521028 7521998 Fax 30 210 7560712 www videx gr e mail videx videx gr Danish office VIDEX...