Art. 4833 

 Speaker unit 

SIGNALS

+V

Power input 16÷20Vdc

Power input ground

12Vout

12Vdc. 0,3A max. output to supply accessiories

1

Speech line input toward the loudspeaker and data signal (about 12V in stand-by, about 5V with a conversation in 

progress)

2

Speech line output from the microphone (about 12V in stand-by, about 3V with a conversation in progress)

V1

Balanced video signal sync.–

V2

Balanced video signal sync.+

BS

Input/Output busy signal (about 12V in stand-by, about 0V with a call in progress)

SL

Active low output to enable the enslavement relay for video signal exchange (active with a call in progress)

PTE

Active low input to control directly the door open relay

C

Door open relay common contact

Max 24Vdc, 3A when used as dry contacts relay

NC

Door open relay normally closed contact

NO

Door open relay normally open contact

TECHNICAL SPECIFICATION
Power Supply:

 

Supplied by the BUS line, 20Vdc

Power consumption:

  

Stand-by:  70mA 

 

Operating: 250mA

Working Temperature:

  -10 +50° C

Содержание 4833

Страница 1: ...ances The LED will be off when the system is in stand by If illuminated indicates that the call from the outdoor station is in progress The LED will switch OFF when the call is answered or after the programmed number of rings If illuminated indicates that it is possible to speak because the call has been answered The LED will switch OFF at the end of a conversation or at the end of the conversatio...

Страница 2: ...elay operating mode is set to capacitor discharge one terminal of the electric lock must be connected to ground while the second must be connected to NO terminal The NO terminal will supply a temporary voltage when the speaker unit receives the door open command BUILT IN RELAYS BACK EMF PROTECTION The Art 4833 includes selectable back EMF protection on the relays The jumpers marked J4 One jumper f...

Страница 3: ...ess V1 Balanced video signal sync V2 Balanced video signal sync BS Input Output busy signal about 12V in stand by about 0V with a call in progress SL Active low output to enable the enslavement relay for video signal exchange active with a call in progress PTE Active low input to control directly the door open relay C Door open relay common contact Max 24Vdc 3A when used as dry contacts relay NC D...

Страница 4: ...66251090 EN V2 1 15 05 16 4 4000 Series Art 4833 Installation instructions Art 4833 Speaker unit ...

Страница 5: ...08 01 2008 08 01 2008 VK4K VK4K S CVK4K CVK4K S VK4K VK4K S CVK4K CVK4K S SE 12VAC ART 850K TRASFORMATORE TRANSFORMER Art 850K 24V 230Vac 0 127Vac Art 3356 3456 VIDEOCITOFONO VIDEOPHONE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 R1 Art 3980 1 2 3 4 5 6 7 8 ON 1 2 ON Push to Exit Local Bell Door Monitor NC V2 BS PTE SL V1 2 1 12Vout V C NO 4 3 2 1 ON 1 Art 4833 1 SE 12Vdc Using Electric Lock 12Vd...

Страница 6: ...66251090 EN V2 1 15 05 16 6 4000 Series Art 4833 Installation instructions Notes ...

Страница 7: ...66251090 EN V2 1 15 05 16 7 4000 Series Art 4833 Installation instructions Notes ...

Страница 8: ...0 210 7521998 Fax 30 210 7560712 www videx gr videx videx gr Danish office VIDEX DANMARK Hammershusgade 15 DK 2100 COPENHAGEN Phone 45 39 29 80 00 Fax 45 39 27 77 75 www videx dk videx videx dk Benelux office VIDEX BENELUX E3 Iaan 93 B 9800 DEINZE Phone 32 9 380 40 20 Fax 32 9 380 40 25 www videxbenelux be info videxbenelux be CUSTOMER SUPPORT All Countries VIDEX ELECTRONICS S P A www videx it tec...

Отзывы: