![Videx 3676 Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/videx/3676/3676_installation-manual_1016240003.webp)
66251010-EN - V2.1 - 31/05/16
3
3600 Series
Art. 3676 - Installation instructions
VIDEOMONITOR/INTERCOM ADDRESS, VIDEO MODE AND TERMINATION SETUP
Each intercom is addressed in binary (PHONE ID) using the 8 way dipswitches located on the rear of the unit. Each switch corre-
sponds to one bit which can have a value 0 (OFF) or 1 (ON). Each bit corresponds to a decimal weight depending on the position:
Switch 1 = decimal 1, 2=2, 3=4, 4=8, 5=16, 6=32, 7=64, 8=128. I.E. to set the address 37, put switches 1, 3 and 6 on (1+4+32=37).
SWITCHES
DECIMAL WEIGHT
ADDRESS
8
7
6
5
4
3
2
1
128
64
32
16
8
4
2
1
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
0
0
0
0
0
0
0
1
1
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
0
0
0
0
0
0
1
0
2
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
0
0
0
0
0
0
1
1
3
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
0
0
0
0
0
1
0
0
4
OFF
OFF
ON
OFF
OFF
ON
OFF
ON
0
0
1
0
0
1
0
1
37
ON
OFF
ON
ON
OFF
ON
OFF
OFF
1
0
1
1
0
1
0
0
180
SIGNALS ON CONNECTION BOARD
+20V
1
Video power supply 17÷20Vdc
+20V
2
Video power supply 17÷20Vdc
GND
3
Video power supply ground reference
GND
4
Video power supply ground reference
V2/V
5
Balanced video signal V2 sync.(balanced video signal mode)
Composite video signal (coax video signal mode)
V1
6
Balanced video signal V1 sync.(balanced video signal mode)
L
7
BUS line
GND
8
BUS line ground reference
LB
9
Local bell input (active low)
AL
10
Alarm input (active low)
11
SB
12
Service Push button (close to ground when pressed)
EXTC
13
Call tone output for extension sounder like Art. 512A
14
+VD
15
+12Vdc output to supply the video distributor Art. 894/Art. 894N
GND
16
Ground
LDO
19
Auxiliary LED (
button) power supply input
GND
20
Ground
TECHNICAL SPECIFICATION
Working Voltage:
17÷20Vdc
Power Consumption:
Standby: 12mA
During a conversation: 250mA Max (on 20Vdc)
Working Temperature:
-10°C +50°C
Art. 3676
Digital videophone for VX2200 Digital System