Instruc
tion manual - English - EN
3
MNVKOHEGB_1702_EN
6 Connections
Before starting any operation, make sure
the power supply is disconnected.
Never power the kit with a voltage different
from the one indicated.
CAUTION! The type of cable used must be
compatible with the planned use. Comply
with the national regulations in force on
electrical installation.
Earth cable should be about 10mm longer
than the other two, so that it will not be
disconnected accidentally if pulled.
Connect the safety earth to the relative
terminal of the power supply connector.
Open the box unscrewing the screws.
Insert the cables inside the weatherproof box using
the cable glands.
Connect terminal J3 to the camera.
Connect the power supply terminal J1 to the electric
network.
J1
J3
Fig.
1
View inside airtight casing
V
IN
V
OUT
Fig.
2
The supplied board
Nominal section of the cables used: from
0.5mm² up to 2.5mm².
Close the box.
Содержание OHEGBPS1B
Страница 2: ......
Страница 21: ...RU 3 MNVKOHEGB_1702_RU 6 10mm J3 J1 J1 J3 1 VIN VOUT 2 0 5mm 2 5mm...
Страница 23: ......