Digital Recorder
29
12.6 Physical and Environmental
12.6.1 Power
Requirements
Power supply switch set to 115V
Power supply switch set to 230V
Voltage
90-135 Vac 47-63Hz
180-265 Vac 47-63Hz
Current
2A maximum
1A maximum
12.6.2 CE
Marking
This product is CE marked. It has been fully tested and complies with 89/336/EEC
Electromagnetic Compatibility and 73/23/EEC Low Voltage directives, and with EN
60950:2000 safety standards.
Warning
: This is a Class A product. In a domestic environment this product may cause
radio interference in which case the user may be required to take adequate measures.
12.6.3
Dimensions and Weight
Width
Height
Depth
Weight
Unit 165mm
200mm
310mm
6Kg
Packaged 275mm
380mm
475mm
8Kg
12.6.4
Temperature and Humidity
Operating
Storage
Temperature
10 to 35 º C
-20 to 60 º C
Humidity
5 to 95% non-condensing
5 to 95% non-condensing
12.6.5 Ventilation
The Vi100 Digital Recorder has ventilation holes in the base, front and rear. Using internal
fans, the unit creates a continuous flow of air through the unit to control the temperature of
the disc drives and other internal components.
The ventilation holes must not be obstructed otherwise the lifetime and reliability of the
system may be affected.
12.6.6 Safety
For warranty and safety reasons, the cover of this equipment must not be removed. There
are no user serviceable parts inside.
Содержание Vi100
Страница 2: ...Vi601d doc...
Страница 16: ...Digital Recorder 12 DEC INC...
Страница 34: ...Digital Recorder 30...
Страница 36: ...Digital Recorder 32...
Страница 37: ...Digital Recorder 33 Notes...