TDE-700 Decoder 

HOUSE 8     7     6     5      4      3      2      1

Bus In

Bus Out

Power Indicator   Power Exit

 

 

Dimension 310mm(W) x 56mm(H) x 180mm(D) 

TDE Port : 

to Main Controller or Next

       

    

Decoder’s Bus In 

ÅÆ

 Bus Out 

 
 
                                                 S VDD(red) 
                                             GND(black) 
                                          RX Data(brown) 
                                      TX Data(purple) 
                                   Audio 0(orange) 
                               Audio 1(blue) 
                             Audio for Guard(green) 
                         Not in Use 
                     Not in Use 
                 Video(yellow or Coax) 

 
House 8 ~1 Ports : 

to Handsets 

  

 
 
                                      VDD(red) 
                                   GND(black) 
                               AUDIO(blue) 
                            DATA(white) 
                        VIDEO(yellow) 

TLC-700 Lift Controller 

TLC

5~1

10~6

15~11

16

 

 

Dimension 310mm(W) x 56mm(H) x 180mm(D) 
5~1     : Associated output for Level 1~5 
10~6    :Associated output for Level 10~6 
15~11 :Associated output for Level 15~11 
16        :Associated output for Level 16                                                          Level 0 
                                                                                                                       Level 0 
These outputs are ‘dry contact’(no voltage)  only.                                  Level 1 
                                                                                                                Level 1 
 TLC Port : Connect to TLC Port on Main Controller                        Level 2 
                                                                                                          Level 2 
                                                                                                  Level 3 
                                                                                                  Level 3 
                                                                                           Level 4 
                                                                                           Level 4 

TDS-700 Display Unit 

TDS

Reset

 

 

Dimension  310mm(W) x 180mm(D) x 56mm(H) 
 
Displays the unit No. when residents call guard station. 
An alarm sounds and displays unit No. when a panic button is pressed. 
Press RESET button to cancel the alarm sound and reset the display. 
Displays all status and entry in programming mode. 
TDS Port : Connect to TDS Port on the Main Controller 

 
 
 

1       2      3

4       5      6

7       8      9

0      #

*

TVE-700 Video Entrance Station 

# button : Reset / Door open password entry mode 
 button : Guard Call 
 

Microphone Adj.     Speaker Volume Adjustment 

 
 
                                              

N.B: Door Lock contacts are  

                                                      

A ‘voltage free dry contact’

                                         Door Lock:Normally Close(Orange) 
                                      Door Lock: Normally Open(Purple) 
                                   Door Lock: Common(Green) 
                        Video Output(Yellow) 
                     Data(white) 
                 Audio(blue)                         to Main Controller 
              GN(black)                             (TMC-700) TVE port 
           S VDD(red) 
Dimension 
Overall 192mm(W) x 279mm(H) x 12mm(D) 

Cutout  163mm(W) x 256mm(H) x 55mm(D) 

 

 

 

TMN-700 Video Handset 

Monitor/Key button : Press to open associated door. 
                                 Press to display entrances on monitor. 
Panic button     : Press 2 Seconds to call Guard Station 
Red LED:         : Normally Off, Blinks when guard has a  
                           Message. Automatically off when calls the  
                           Guard station by picking up the hand piece. 
                    --- VDD(red) 
                    --- GND(black) 
                    ---  AUDIO(blue) 
                    --- DATA(white) 
                    --- VIDEO(yellow) 
 
1R,2W, 3Y,4B terminal to Private Entrance Station(TPV-700) 
Dimension 182mm(W) x 216mm(H) x 52mm(D) 

 

 

 

 

THS-700 Audio Handset 

Out Door button : Press to talk to the Private Entrance Station 
Panic button     : Press 2 Seconds to call Guard Station 
Message LED   : Normally Off, Blinks when guard has a  
                           Message. Automatically off when calls the  
                           Guard station by picking up the hand piece. 
Door LED          : Will be on when Door Button is pressed. 
               Connector signals are same as Video Handset without 
Video Signal. 
Dimension 107mm(W) x 218mm(H) x 70mm(D) 

 

Содержание Digital 700

Страница 1: ...tiple Riser Port 1 2 3 4 5 6 7 8 9 0 VIDEOMAN SYSTEMS Co V 3 0 21 9 01 VIDEOMAN Systems Co Unit 13 112 Benaroon Rd BELMORE NSW 2192 AUSTRALIA Phone 02 9758 9509 Fax 02 9758 9510 e mail info videoman c...

Страница 2: ...4 5 Mounting Entrance Station 6 General Wiring Guide 7 Wiring Requirement Single Riser Configuration 8 Wiring Requirement Multiple Riser Configuration 9 Connection Diagram 10 11 System Programming 12...

Страница 3: ...roperly Which eliminates huge time and effort in rectifying the problem Connectors for all necessary connection no screws Programmable lift controller Each unit has its own level No in programming pro...

Страница 4: ...al audio conversations can be made on a system simultaneously The second call and voice conversation from different Entrance station to different Handset can be made even if someone uses the system Pl...

Страница 5: ...ore N A Between Main controller Decoder 0 44 mm 2 7core shielded 1 5 mm 2 2core 0 44 mm 2 6core shielded RG59 Coax 1 5 mm 2 2core Between Decoder Handset 0 44 mm 2 5core shielded 0 44 mm 2 3core shiel...

Страница 6: ...A Ver 1 1 Pjt No t5s4v2 Eos Australia P L Date 15 09 01 A B E A 7 core 14 020 Shielded Cable 0 44mm2 B 2 core 14 020 Cable 0 44mm2 C 3 Core 14 020 Shielded Cable 0 44mm2 D 5 Core 14 020 Shielded Cable...

Страница 7: ...5 4 3 2 1 1st 16th Floor DC PowerJack TVE700 TVE700 Video Entrance Station DOOR LATCH DOOR LATCH TVG700 Video Guard Station TLC700 Lift Controller TDS700 Display Unit TMN700 Video handset Power Exit P...

Страница 8: ...minutes c Main Controller ID No 00 49 When there is only one Main controller enter 00 by pressing key Please skip this step if there is no Master Station by pressing key Enter associated 4 digit No ex...

Страница 9: ...ept existing Level No The first two digit must be 06 12 Repeat step 8 9 10 for next unit Depending on the physical port socket location in the system c Socket No on Decoder 0 9 d Decoder No on the Sys...

Страница 10: ...S Port on the Main Controller 1 2 3 4 5 6 7 8 9 0 TVE 700 Video Entrance Station button Reset Door open password entry mode button Guard Call Microphone Adj Speaker Volume Adjustment N B Door Lock con...

Страница 11: ...guard station Dimension 107mm W x 218mm H x 70mm D TPS 24 Power Supply 24V DC 2 0Amp SMPS power supply Dimension 84mm W x 146mm H x 48mm D Special Extras Long distance interface unit for the Guard Sta...

Страница 12: ...06 9 06 0 06 0 06 1 06 1 06 2 06 2 06 3 06 3 06 4 06 4 06 5 06 5 06 6 06 6 06 7 06 7 06 8 06 8 06 9 06 9 06 Hard No Decoder Socket No Hard No Decoder Socket No Riser No 0 5 Dec No 0 49 Plug No Soft No...

Отзывы: